USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 5 of 5
Power-Flo II
Rev. A
3. Block off suction as close to pump as possible and determine if pump will develop a vacuum.
a) If pump does not develop vacuum, and pump has sufficient «priming water»:
1. Tighten all bolts and fittings on suction side.
2. Check voltage to make sure pump is up to speed.
3. Open pump and check for clogging or obstruction.
4. Remove and replace shaft seal.
b) If pump develops a vacuum, check for blocked suction line or strainer, or air leak in suction piping.
E) Low flow - Generally, Check for :
1. Clogged or restricted strainer or suction line; undersized pool piping.
2. Plugged or restricted discharge line of filter (high discharge gauge reading).
3. Air leak in suction (bubbles issuing from return fittings).
4. Pump operating under speed (low voltage).
5. Plugged or restricted impeller.
F) Noisy pump - Check for
1. Air leak in suction causing rumbling in pump.
2. Cavitation due to restricted or undersized suction line and unrestricted discharge lines.
Correct suction condition or throttle discharge lines, if practical.
3. Vibration due to improper mounting, etc.
4. Foreign matter in pump housing.
5. Motor bearings made unserviceable by wear, rust, or continual overheating.
Summary of Contents for Power-Flo II
Page 50: ...HAYWARD 4 5 Power Flo II A 1 2 Hayward 3 4 5 Hayward 1 2 A 1 2 B 1 2 3 C 1...
Page 51: ...HAYWARD 5 5 Power Flo II A D 1 2 3 a 1 2 3 4 b E 1 2 3 4 5 F 1 2 3 4 5...
Page 53: ...Page 43 Power Flo II Rev A 1 3 2 4 5 6 11 7 8 9 10 12 13 14 15 16 17 17...
Page 58: ...Page 48 Power Flo II Rev A HAYWARD 2 HAYWARD HAYWARD HAYWARD HAYWARD...
Page 59: ...Hayward is a registered trademark of Hayward Industries Inc 2013 Hayward Industries Inc...