Compatibility

The Hayward OmniPL Retrofit Kit is designed to convert your old ProLogic, AquaLogic or AquaPlus into a web enabled pool automation control with convenient 

touchscreen interface. The conversion offers the next generation of technology to manage pool/spa equipment, allowing communication to web connected 

computers and mobile devices. You can now conveniently monitor your pool/spa and change settings anytime and from anywhere.

This OmniPL Retrofit Kit is compatible with all “P-4”, “PS-4”, and “PS-8” units. The HLXPROUPG is not compatible with “PS-16” although two kits could be 

installed (one in PS-16, one in the Expansion unit) to manage one pool. For this operation, separate the control into two sites in the mobile app.   

The current control’s configured equipment, timers and settings will be lost after replacing the main printed circuit board (mainboard) with the OmniPL Retrofit 

Kit mainboard. It’s important to capture all of this information before starting the installation. A worksheet is provided on the following pages to record all current 

settings.

This upgrade will convert the current control to the Omni family of products and will require Omni specific accessories. Some ProLogic, AquaLogic or AquaPlus 

accessories will no longer work with the OmniPL after upgrading. If you are currently using a wired or wireless remote control or an AQL-CHEM Sense and 

Dispense Kit with your control, be aware that those items will not work after the upgrade.  A list of Omni compatible accessories are listed below. 

HLWALLMOUNT 

 

Wired Wall Mount Remote Terminal 

HLWIRELESS 

 

Portable Wireless Remote Terminal

HLSPASIDE 

 

Wired Spa Remote

HL-CHEM  

 

ORP & pH Sensing Kit for monitoring and controlling pool chemistry

NOTE: For systems using a Hayward Ecostar VSP running firmware version less than R3.0.5 (pumps built before 2014), a Hayward SPX3400LCD display must 

be purchased and installed on the EcoStar pump if variable speed operation is desired with the OmniPL. If single speed control is desired, no changes are 

necessary.

NOTE: If the control is using networked ColorLogic Lights, the lights must be put into “Standalone” (default) mode before disconnecting the control. The OmniPL 

can only control ColorLogic lights in “Standalone” mode.

FCC Statement

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by Hayward could void the user’s authority to operate this equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 

try to correct the interference by one or more of the following measures:

--  Reorient or relocate the receiving antenna.

--  Increase the separation between the equipment and receiver.

--  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

--  Consult the dealer or an experienced radio / TV technician for help.

Industry Canada Statement

 

This Class B digital apparatus complies with Canadian ICES-003.  

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

The term “IC” before the certification / registration number only signifies that the Industry Canada technical specifications were met.

Summary of Contents for OmniPL HLXPROUPG

Page 1: ...dustries 400 Connell Drive Suite 6100 Berkeley Heights NJ 07922 Phone 908 355 7995 www hayward com OmniPL Retrofit Kit Installation Manual HLXPROUPG Contents Before You Begin 1 Worksheet 2 Installation 4 Connection Table 7 Configuration 8 Automation and Chlorination ...

Page 2: ...nstalled on the EcoStar pump if variable speed operation is desired with the OmniPL If single speed control is desired no changes are necessary NOTE If the control is using networked ColorLogic Lights the lights must be put into Standalone default mode before disconnecting the control The OmniPL can only control ColorLogic lights in Standalone mode FCC Statement This device complies with part 15 o...

Page 3: ... in a location that is convenient for the user to periodically view and change pool spa settings Lastly the Controller contains the Wifi radio and its location should be considered if planning to use a wireless connection to the home router or access point A wireless mobile device phone tablet etc could be used to test the signal strength at the intended mounting location The Controller features a...

Page 4: ...Function Manual On Off Timeclock Countdown Timer Solar Low Speed Interlock Enabled Disabled Freeze Protection Enabled Disabled Aux3 Config Function Manual On Off Timeclock Countdown Timer Solar Low Speed Interlock Enabled Disabled Freeze Protection Enabled Disabled Aux4 Config Function Manual On Off Timeclock Countdown Timer Solar Low Speed Interlock Enabled Disabled Freeze Protection Enabled Disa...

Page 5: ...s _______to_______ Weekdays _______to_______ Aux2 All Days Weekends _______to_______ Weekdays _______to_______ Aux3 All Days Weekends _______to_______ Weekdays _______to_______ Aux4 All Days Weekends _______to_______ Weekdays _______to_______ Aux5 All Days Weekends _______to_______ Weekdays _______to_______ Aux6 All Days Weekends _______to_______ Weekdays _______to_______ Valve3 All Days Weekends ...

Page 6: ...ecting the connector shown above Rectifier wiring These red black and orange wires must be removed from both ends mainboard and recti fiers and discarded This wiring will not be used with the OmniPL mainboard To maintain enclosure integrity do not remove rectifiers Input power wiring These black and white wires will be connected to Wago lever connectors on a wiring harness that plugs into the Omni...

Page 7: ... supplied wiring harnesses using the colors as a reference for each connection blue to blue purple to purple etc The yellow secondary transformer leads will connect to the supplied wiring harness shown below The harness and the yellow transformer leads will need to be cut and stripped before inserting into the Wago lever connectors TurboCell connector is the same as old control Used for optional H...

Page 8: ... page 26 To mount screw two appropriate fasteners into the mounting surface at the desired location as shown below Tighten until the bottom of the screw heads are 1 8 off the mounting surface Position the Con troller cutouts over the screw and slide the unit downward You may have to tighten or loosen the screws slightly to fully engage the screw heads to get a snug fit Run the Controller s 15 ft c...

Page 9: ... the table below You ll be prompted to provide which pool equipment is connected to each Connection ID Because the control was previously wired take this time to go through each connection and fill out the table Refer to the graphic below for the physical location of these connections HVR1 HVR2 HVR3 HVR4 HVR5 HVR6 HVR7 HVR8 When using Optional Smart Relays ID ...

Page 10: ...mniPL requires knowledge of all of the connected pool equipment so have the Connection Table page 7 handy while configuring the OmniPL If you are asked a question and don t know the answer in many cases you ll be able to skip the question and proceed In some cases the Configuration Wizard will require an answer Answer the question to the best of your ability and take note as you ll be able to go b...

Page 11: ...ayed This unique number is used to identify your OmniPL when setting up a web account A web account is needed to access the OmniPL over the web by mobile devices IMPORTANT write down the MSP ID number for future use The MSP ID number will be needed when entering the configuration wizard after initial configuration as well as entering and exiting Simple Mode Simple Mode is a customizable screen tha...

Page 12: ...ng If Yes is selected Freeze Protection Temperature Select the temperature to be used for freeze protection Temperature is adjustable from 33ºF 42ºF 1ºC 6ºC 38ºF 3ºC is default This threshold will be used for all outputs that have freeze protection enabled If VSP is selected Which Hayward Unique Address If using a VSP you ll be asked what is the Hayward Unique Address HUA If a value is already sho...

Page 13: ...me will be used when referring to this particular heater Which Relay is it Wired to Selecting the box will bring you to a table showing all detected relays Select the low voltage relay that is wired to the heater refer to the Connection Table for this information then advance The relay should now be shown in the box Advance to the next screen to continue gas heater configuration If more than one h...

Page 14: ...ets the demand within this time frame the next heater will not be used Minimum Operation Speed Select the lowest pump speed that is allowed while solar heating Set a speed that will ensure that there will be sufficient flow for the solar heating system to operate properly Would You Like To Prioritize The Use Of Solar Heating Over Any Other Types Select the lowest pump speed that is allowed while s...

Page 15: ...Output The OmniPL can only generate chlorine while the filter pump is operating Set the percentage of run time that you desire chlorine generation Raise this value to generate more chlorine Lower this value to generate less Is pH Reduction Enabled Select Yes if you have a dispenser to lower pH connected to the OmniPL If Yes is selected Are you Using Acid or CO2 Select one How Many Acid CO2 Dispens...

Page 16: ...to Enable Priming Select whether you want the pump to prime when turned on This will turn the pump on at high speed for 3 minutes to establish normal water flow every time the pump is activated after being off for at least 30 seconds Does Cleaner have a Valve Select whether the cleaner requires a valve to change position when in use If Yes is selected How Many Select how many valves are used for t...

Page 17: ...mal water flow every time the pump is activated after being off for at least 30 seconds Water Feature Wired to a Relay Select whether the water feature requires the use of a high voltage relay If Yes is selected Select Relay Touching the box will bring you to a table showing all detected relays Select the relay s that is connected to the water feature and touch the Done button The relay should now...

Page 18: ...cessory is scheduled to run If Yes is selected What Type Select the type of pump used The choices are Single Speed Two Speed and VSP If single speed or two speed pump is selected Which Relay is it Wired to If using a single speed or two speed pump you ll be asked which relay s is wired to the pump Select the proper relay s from the table and touch the Done button The relay s should now be shown in...

Page 19: ... with Body of Water 1 If Yes is selected Your system will be fully shared which means your filter pump heaters chemistry will be shared between both Bodies of Water You can now set your filter pump and heater settings for this body of water If No is selected You will begin dual equipment setup for you second Body of Water This means that your filter pump and chemistry will not be shared between bo...

Page 20: ...and you can advance to the next screen to continue configuration Do You Want to Configure Any Backyard Lights Select yes if you are using any type of pool spa or outdoor lights The options are Universal ColorLogic UCL ColorLogic 4 0 CL4 0 ColorLogic 2 5 CL2 5 Pentair Color LED P COLOR Jandy Color LED Z Color Incandescent and Other Transformers powering Universal ColorLogic lights must all be conne...

Page 21: ...int For external inputs affected equipment will turn on off when the switch is actuated Advance through the configuration and when finished a summary screen will be displayed The summary will describe how the interlocked equipment will function Read through the description and make sure the equipment will function as desired If Equipment to Mode is selected With Equipment to Mode interlock affecte...

Page 22: ...tem These buttons are as follows Save Touch this button to save the configuration edit This button only appears on the Quick Edit Home screen Cancel Touch this button to cancel any changes made to the configuration and exit Quick Edit This button only appears on the Quick Edit Home Screen Home Touch this button to quickly jump back to the Quick Edit Main Menu Screen to save your changes This butto...

Page 23: ... want the Filter Pump to shut off while valves are turning Flow Monitoring Select whether you want flow to be monitored in this Body of Water Priming Select whether you want the Filter Pump to prime This option only appears if the FIlter Pump is configured as a 2 Speed or Variable Speed Pump Freeze Protect Select whether you want the Filter Pump to turn on for Freeze Protection Also set the Freeze...

Page 24: ...blet feeder Dispenser Relay or Valve Depending on your dispenser type select the output that controls the dispenser ORP Timeout Choose the ORP timeout time and desired ORP setpoint This option is only available if ORP controls chlorination Delete Chem Sense Module Chlorination From this screen if you wish to delete any currently configured chemistry options select the trash can on the right of the...

Page 25: ...ell as the Low Medium and High speed settings This option only appears if the water feature pump is configured as a Variable Speed Pump Priming Select whether you want the water feature pump to prime This option is only available if the water feature pump is config ured as a 2 Speed or Variable Speed Pump Freeze Protect Select whether you want the water feature to turn on for Freeze Protection Als...

Page 26: ...e This is where you will be allowed to rename the Body of Water that you are currently configuring to whatever name you desire If Backyard is selected Select the Equipment that you would like to configure The options are Add Standalone Light and Add Accessory The configuration for these are described in the Configuration Wizard portion of this manual If Standalone Light is selected Add Standalone ...

Page 27: ...f there are currently no interlocks configured on your system then the button will appear as Add Interlock instead of Interlocks In this case pressing Add Interlock will take you through the full configuration for adding a new interlock These steps are described in the Configuration Wizard por tion of this manual Once an interlock has been created the button will say Interlocks If System Options i...

Page 28: ...To change functions or assign a new function select the button that you d like to configure If an Aux button is selected Select Function There are 4 options available Equipment Pressing this button will bring you to a screen that shows all available equipment Select the desired equipment that you want to assign to the Aux button Favorite Pressing this button will bring you to a screen that shows a...

Page 29: ...st Hayward autho rized warranty service center For more information on authorized service centers please contact the Hayward Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Hayward web site at www hayward com WARRANTY EXCLUSIONS 1 Material supplied or workmanship performed by others in process of installation 2 Damage resulting from improper installation inc...

Page 30: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 28 ...

Page 31: ...29 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Page 32: ... Hayward Industries Inc 2021 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third parties FOR FURTHER INFORMATION OR CONSUMER TECHNICAL SUPPORT VISIT OUR WEBSITE AT www hayward com ...

Reviews: