background image

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Page 17 of 24 

Max-Flo VS Pump

 

IS2300VSP   Rev C 

6.11.

 

Reset to Factory Settings 

Screen 

Buttons 

Used 

Comments 



 

RUN 

STOP 

Press and Hold RUN/STOP and apply 

power to the pump 

Note:

 The pump may be set back to factory settings.  To reset the pump to factory settings remove power from the 

pump.  Press and Hold the RUN/STOP button and apply power to the pump.  When the pump turns back on it will 
display the message above and reset all settings back to factory settings. 

7.

 

Maintenance 

 

Clean strainer basket regularly.  Do NOT strike basket to clean.  Inspect strainer cover gasket regularly and replace as 
necessary. 

 

Hayward pumps have self-lubricating motor bearings and shaft seals.  No lubrication is necessary. 

 

Keep motor clean.  Insure motor air vents are free from obstruction to avoid damage.  Do NOT use water to hose off 
motor. 

 

Occasionally, shaft seals must be replaced, due to wear or damage.  Replace with genuine Hayward seal assembly 
kit.  See “Shaft Seal Change Instructions” in this manual. 

8.

 

Storage / Winterization 

 

WARNING

 

– Separation Hazard

.

  Do not purge the system with compressed air.  Purging the system with 

compressed air can cause components to explode, with risk of severe injury or death to anyone nearby.  Use only a 
low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping. 

 

ATTENTION

 – Allowing the pump to freeze with water in it will void the warranty. 

 

ATTENTION

 – Use ONLY propylene glycol as antifreeze in your pool/spa system.  Propylene glycol is non-

toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic 
components in the system. 

Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time 
(see instructions below).  Gravity drain system as far as possible. 

Keep motor dry and covered during storage.  To avoid condensation/corrosion problems, do NOT cover or wrap pump 
with plastic film or bags. 

8.1.

 

Storing Pump For Winterization 

 

WARNING

 

– 

To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining 

pump.  Failure to disconnect power may result in serious personal injury or death. 

1.

 

Drain water level below all inlets to the pool. 

2.

 

Remove drain plugs and strainer cover from strainer housing. 

3.

 

Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping. 

4.

 

Once the pump is fully drained of water, re-install the strainer cover and drain plugs.  Store pump in a dry area. 

Summary of Contents for Max-Flo VS SP2300VSP

Page 1: ...ilters heaters and pool cleaning equipment The totally enclosed permanent magnet motor combined with its advanced hydraulic design provides unparalleled energy savings Max Flo VS is designed for pools...

Page 2: ...11 5 1 Input Power Wiring 11 6 Startup Operation 11 6 1 Prior to Start Up 11 6 2 Starting Priming the Pump 11 6 3 User Interface Summary 12 6 4 Menu Outline 13 6 5 Initial startup 13 6 6 Configuration...

Page 3: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 3 of 24 Max Flo VS Pump IS2300VSP Rev C 11 Troubleshooting 20 11 1 General Problems 20 11 2 Error Codes 22 12 Warranty 22 13 Product Registration 23...

Page 4: ...Electric Code NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SPE...

Page 5: ...NING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a pr...

Page 6: ...e in off position and filter manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not c...

Page 7: ...mperatures below freezing without issue 2 3 Product Dimensions 3 Energy Efficiency Overview The energy consumed by a pool pump is measured in terms of Watts W or Kilowatts kW The Max Flo VS displays p...

Page 8: ...erate the pump at higher speeds for the shorter periods of time needed to operate a heater water feature etc 4 Installation and Wiring WARNING This product should be installed and serviced only by a q...

Page 9: ...layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT attempt to force...

Page 10: ...urrent passing between bonded metal objects which could potentially cause electrical shock if grounded or shorted Reference NEC codes for all wiring standards including but not limited to grounding bo...

Page 11: ...pressure test prior to initial use to ensure plumbing system is functioning properly then the following criteria should be maintained for this test 1 Have a professional perform this test 2 Ensure all...

Page 12: ...TION Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES in suction and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve See...

Page 13: ...creen information when pressed If the DISP FUNC button is held for several seconds it will enter the controller into configuration mode The and arrow buttons are used to change parameters within confi...

Page 14: ...rotating block to emphasize the pump is in prime mode Note When Pump has finished Priming the pump will start speed V3 and display RPM Speeds can be selected at this time to temporarily run the pump h...

Page 15: ...ttings excluding the current screen settings and exit configuration mode Note The maximum allow speed for speeds V1 through V3 is 3 000 RPM The minimum allowable speed for V1 through V3 is 600 RPM The...

Page 16: ...FLASH A list of these error codes can be found in section 11 2 The cause of the internal error should be investigated and fixed before continuing to run the pump When the cause of the error has been f...

Page 17: ...sed air can cause components to explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping ATTENTION...

Page 18: ...the back of the pump 4 Remove the impeller by rotating counterclockwise 9 3 Removing the Ceramic Seat 5 Remove the spring seal assembly and seal plate from the motor by removing the four 4 3 8 x 1 bol...

Page 19: ...gasket is in place and lubricated Replace if damaged Tighten bolts alternately and evenly to 185 inch pounds Looking at the back of the pump start with the top right move diagonal to the bottom left t...

Page 20: ...bly includes parts 7 14 motor and drive 1 11 Troubleshooting 11 1 General Problems Motor Will NOT Start 1 Make sure the terminal board connections agree with the wiring diagram on the pump data plate...

Page 21: ...s Check if all system hose clamps are tight ii Check voltage to ensure that the motor is rotating at full rpm s iii Open the housing cover and check for clogging or obstruction in suction Check the im...

Page 22: ...f the error should be investigated and resolved before continuing normal operation of the pump When the issue has been resolved press the RUN STOP key to clear the error message Screen Buttons Used Co...

Page 23: ...2300VSP Rev C DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING AT 3 000 RPM CLEAN FILTER _______________________ PUMP MODEL __________________ 13 Product Registration Retain th...

Page 24: ...ll e mail communications regarding Hayward Equipment or promotions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LINE AT WWW HAYW...