Fault
Error codes
Description
Solution
Water inlet sensor fault
P01
The sensor is open or has
short-circuited.
Check or replace the sensor.
Water outlet sensor fault
P02
The sensor is open or has
short-circuited.
Check or replace the sensor.
Outside temperature sensor
fault
P04
The sensor is open or has
short-circuited.
Check or replace the sensor.
De-icing sensor fault
P05
The sensor is open or has
short-circuited.
Check or replace the sensor.
High pressure protection
E01
Refrigerating circuit pressure
too high or water flow too low
or coil obstructed or air flow
too weak.
Check the high pressure switch
and the refrigerating circuit
pressure.
Check the water or air flow.
Check the flow controller is
working properly.
Check that the water inlet/outlet
valves are opening.
Check the by-pass settings.
Low pressure protection
E02
Refrigerating circuit pressure
too low or air flow too weak or
coil obstructed.
Check the low pressure switch
and the refrigerating circuit
pressure to see if there is a leak.
Clean the coil surface.
Check the fan rotation speed.
Check the free circulation of air
through the coil.
Flow sensor fault
E03
Insufficient water flow or
sensor short-circuited or faulty
Check the water flow, check the
filtration pump and flow sensor
for any faults.
Temperature difference too
great between the outlet and
inlet water
E06
Insufficient water flow volume,
water pressure difference too
low/too high.
Check the water flow or for a
system obstruction.
Cold mode protection
E07
Water output quantity too low. Check the water flow rate or the
temperature sensors.
Communication problem
E08
LED controller or PCB
connection fault.
Check the wiring.
Level 1 antifreeze protection
E19
Air and inlet water temperature
too low.
Turn off the heat pump and drain
the capacitor. Freezing risk.
Level 2 antifreeze protection
E29
Air and inlet water temperature
even lower.
Turn off the heat pump and drain
the capacitor. Freezing risk.
Certain operations must be performed
by an approved engineer.
Summary of Contents for HP3005AT1RM
Page 2: ......
Page 3: ...POMPE A CHALEUR POUR PISCINE Manuel d instructions et d installation ISHP3005AT1RM ...
Page 23: ...19 Page laissée blanche intentionnellement ...
Page 28: ......
Page 29: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ISHP3005AT1RM ...
Page 49: ...19 Page left intentionally blank ...
Page 54: ......
Page 55: ...UNIDAD DE BOMBA DE CALOR PARA PISCINAS Manual de Instalación e Instrucciones ISHP3005AT1RM ...
Page 75: ...19 Página en blanco intencionalmente ...
Page 80: ......
Page 81: ...BOMBA DE AQUECIMENTO PARA PISCINAS Manual de instalação e de instruções ISHP3005AT1RM ...
Page 101: ...19 Página deixada em branco intencionalmente ...
Page 106: ......
Page 107: ...HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN Einbau Anleitungshandbuch ISHP3005AT1RM ...
Page 127: ...19 Seite bewusst leer gelassen ...