18
6. APPENDICES (continued)
6.2 Heating priority connections Single-Phase Pump
Terminals 1 and 2 deliver a potential-free dry contact,
230 V
/ 50 Hz, no polarity.
Wire terminals 1 and 2 as indicated in the diagram
above, to activate the operation of the filtration pump
in 2-minute cycles each hour if the temperature of the
pool is lower than the set point.
Never connect the power supply of the filtration
pump directly to terminals 1 and 2.
Power supply
230V
/ 50Hz
Monophasic pump
Dry contact 7 A max
OUT2
Summary of Contents for HP3005AT1RM
Page 2: ......
Page 3: ...POMPE A CHALEUR POUR PISCINE Manuel d instructions et d installation ISHP3005AT1RM ...
Page 23: ...19 Page laissée blanche intentionnellement ...
Page 28: ......
Page 29: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ISHP3005AT1RM ...
Page 49: ...19 Page left intentionally blank ...
Page 54: ......
Page 55: ...UNIDAD DE BOMBA DE CALOR PARA PISCINAS Manual de Instalación e Instrucciones ISHP3005AT1RM ...
Page 75: ...19 Página en blanco intencionalmente ...
Page 80: ......
Page 81: ...BOMBA DE AQUECIMENTO PARA PISCINAS Manual de instalação e de instruções ISHP3005AT1RM ...
Page 101: ...19 Página deixada em branco intencionalmente ...
Page 106: ......
Page 107: ...HEIZPUMPENANLAGE FÜR EIN SCHWIMMBECKEN Einbau Anleitungshandbuch ISHP3005AT1RM ...
Page 127: ...19 Seite bewusst leer gelassen ...