33
ONLY USE GENUINE HAYWARD REPLACEMENT PARTS
51300803801 REV B
Figure 25: Manifold Pressure
Connections
Table 11: Required Gas Pressures
(in. wc.)
Measurement Natural Gas
Propane
Manifold
Pressure*
Inlet Pressure,
Minimum
+4.0
+4.0
-0.1 to -0.3
Inlet Pressure,
Maximum
+14.0
+14.0
Manifold pressure
adjustment under
screw cap
Gas Inlet
Pressure Tap
ON / OFF
Switch
Electric
Terminals
Pressure Tap
Vent Tap
Figure 26: Gas Valve