Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
7
Figure 29:
Control box
(shown with
cover removed)
RED - SPA
WHITE – V
COMMON
ORANGE – POOL
Terminal
block for
remote wiring
connections
2-WIRE REMOTE CONTROL CONNECTION:
To configure the heater for 2- wire remote thermostat control, use the “MODE” key on the heater keypad
to put the control into “STANDBY” mode. Then press and hold both the “DOWN” and “MODE” keys for
seconds until the display shows the code “bo”.
On the remote control wiring terminal block (Figure 29), connect the appropriate wires from the remote
control to the terminals adjacent to the ORANGE wire (“POOL”) and WHITE wire (“24V”).
To operate the heater by remote thermostat, the heater’s control must be in either “POOL” or “SPA”
mode. The display will show “bo”. The “POOL” or “SPA” LED will be illuminated. The remote thermostat
will operate the heater. The heater’s thermostat will function to limit the water temperature to a
maximum of
104°F.
3-WIRE REMOTE CONTROL CONNECTION:
On the remote control wiring terminal block (Figure 29), connect the appropriate wires from the remote
control to the terminals adjacent to the ORANGE wire (“POOL”), WHITE wire (“24V”), and RED wire
(“SPA”). To operate the heater with a remote -wire switch, the heater’s control must be in “STANDBY”
mode. The “STANDBy” LED will be illuminated. When the remote switch is set to “Pool/Low” the “POOL”
LED will be illuminated and the water
temperature will be displayed. When the remote switch is set to “Spa/
High” the “SPA” LED will be illuminated and the water temperature will be displayed. The heater will use its
internal thermostat to regulate the water temperature to the set point of the mode selected.