Base Station

Plug in the connector from the wireless base station into the “Wireless” connector on the main PCB in the Aqua

Plus 16v control unit.

Base Station

(AQL2-BASE-RF)

Tighten nut

Aqua Plus
Main PCB

Connector for 
Base Station

AQL-CHEM ORP and pH Sensing Kit

Plug in the connector from the AQL-CHEM into the “AQL-CHEM” connector on the main PCB in the Aqua Plus

16v control unit.

Connector for
AQL-CHEM

Note that all functions in the table may not be offered.  The available functions are dependent on how the Aqua Plus

16v is configured.  For example, if the Aqua Plus 16v is configured for a single heater, “Heater2” will not be

available as an option in the Group menu.  Also, under some circumstances, functions will be displayed but can’t be

changed. Note that the function whose menu you are in, will not be displayed as an option and will automatically

turn on when the group is activated. For example, if programming a Group function under the Lights menu, the

Lights function will not be offered as an option and the Lights function will automatically turn on with the group.

The available control parameters vary with each function.  All functions offer “Unaffected”, which should be

selected if you do not wish to control that particular function within the group.  All other parameters will depend on

the particular function selected.

When activating Group functions, be aware that the most recent Group function that you activate will override any

previous Group functions.

Heater Setpoints in Groups

The Aqua Plus 16v can be programmed to use alternate heater setpoints (conventional and/or solar) while running

group commands. This allows the heater to be set to a higher or lower temperature than normal, while the group is

activated. When the group stops, the setpoint will return to its normal setting.

Changing the setpoint while the Group is running will make the Group release the alternate setpoint control and

revert back to the normal heater setting. Any changes that are made at that point will affect the normal heater

setting.  The next time the Group is activated, the temperature will return to the group setpoint that was originally

programmed in the Configuration Menu. To change the setpoint while the Group is running, go to the Settings menu

and press the +/- button while “Group Control” is displayed.  The setpoint will change and be retained as the new

normal heater setpoint.

Super Chlorinate

The Aqua Plus 16v can be programmed to Super Chlorinate the pool or spa while running a group command.

When the Group starts, the Super Chlorinate cycle will begin.  Super Chlorinate will continue until the preset time

expires (see Timers Menu/Super Chlorinate Hours) or until the Group turns off.  Changing the Super Chlorinate

state using the Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlorinate assigned Aux/Lights/

Valve button will temporarily cancel the Group’s control of Super Chlorinate until the next time the Group is

activated.

Variable Speed in Groups

The Aqua Plus 16v can be programmed to use alternate pump speeds while running group commands. This allows

the pump(s) to be set to a higher or lower speed than normal, while the group is activated. When the group stops,

the speed will return to its normal setting.

Changing the speed setting while the group is running will make the group release the alternate speed setting and

revert back to the normal speed setting. Any changes that are made at that point will affect the normal speed

setting.  The next time the group is activated, the speed will return to the group speed setting that was originally

programmed in the Configuration Menu. To change the speed setting while the group is running, go to the Settings

menu and press the +/- button while “Group Control” is displayed.  The speed setting will change to the normal

speed setting.

20

23

Summary of Contents for Aqua Plus 16v PL-PLUS-16V

Page 1: ...ach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter 1 or hi speed 1 pool filter 2 or lo speed 1 pool filter 3 or hi speed 2 pool filt...

Page 2: ...ytotheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Page 3: ...tion 7 Optional ValveActuators 7 3 Plumbing Standard Pool Spa Configuration 8 Dual Equipment Pool Spa Separate Heaters 9 Dual Equipment Pool Spa Shared Heaters 10 Turbo Cell 11 Flow Switch 11 4 Electr...

Page 4: ...product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation specialist should be con...

Page 5: ...olar thermostat settings Chlorinatorsettings DayandTime Timers Menu Timeclockand orCountdowntimersettings Heater Checkout FollowtheseinstructionstoverifythattheAquaPlus16visproperlycontrollingtheheate...

Page 6: ...the pool per manufacturer s instructions Thisensuresaquick troublefreetransfertotheAquaPlus16vsystem 40 Reset ColorLogic to Default Press Are you sure to proceed ColorLogic reset Confirmed Initiate re...

Page 7: ...peciallyimportantforretrofitinstallationtoolderpoolswhereallofthe chlorineaddedtothepoolovertimeisendingupassalt Ifthelevelislow determinethenumberofgallonsinthe pool and add salt according to the cha...

Page 8: ...4 3 0 1 4 3 5 1 6 2 5 1 6 4 5 2 0 5 5 2 5 8 0 3 6 6 5 2 9 9 0 4 1 7 0 3 2 9 5 4 3 7 5 3 4 10 0 4 5 2 0 91 1 3 91 2 0 91 2 8 1 3 2 3 1 1 1 7 1 1 2 7 1 2 3 3 1 5 3 7 1 7 5 3 2 4 4 3 2 0 4 7 2 1 6 3 2 8...

Page 9: ...r Valve3 Name Waterfall Push to access Valve3 options Rotates between Manual On Off default Countdown Timer Timeclock Solar In floor Cleaner Group and Super Chlorinate Move to previous next configurat...

Page 10: ...theAQL2 BASE RFforallAQL2wirelessremotecontrols Toinstallthebasestation removetheknockout on the upper left side of theAqua Plus 16v main control unit insert the base station and then tighten the nut...

Page 11: ...sing kit Aux1 Relay This feature allows the user to select either Standard default Dimmer ColorLogic or VSP type relay for the Aux1 output The optionalAQL DIM dimmer kit must be installed if Dimmer is...

Page 12: ...ff countdown timer and timeclock functions Move to next menu item Rotates between Manual On Off default Countdown Timer Low Speed Filter Timeclock Solar Low Speed Spa Filter Group Super Chlorinate and...

Page 13: ...et water flowing when the pool spa suction return valves are in any position other than pool only or for the first 3 minutes after solar turns on allows air in the solar panels to be purged Interlock...

Page 14: ...e Aux relays If pool lights are wired to the lights relay some options including Solar function Low Speed of a 2 Speed Filter Pump Lights Interlock and Lights Freeze Protection are not applicable and...

Page 15: ...e between Open and Closed default Move to next menu item or previous next configuration menu External Input The external input device can either be normally open or normally closed In this menu select...

Page 16: ...ove to next menu item Move to next menu item if Solar is enabled if Solar is enabled Allow Low Speed Disabled Toggle between Enabled and Disabled default Move to next menu item or previous next config...

Page 17: ...ext configuration menu if Heater1 is enabled if Heater1 is enabled if Heater1 is enabled display for Heater2 if Heater2 is enabled Heater1 Name Gas Heater Rotates between all available names Move to n...

Page 18: ...Lowest Speed 10 Highest Speed 100 Rotates between 1 speed default 2 speed and variable speed options Toggle between Enabled default and Disabled Freeze Protection Toggle between high speed default and...

Page 19: ...irst 3 minutes of operation anytime the pump has been off for more than 30 seconds Set highest speed from 20 to 100 default Flow Monitor This feature will help protect the filter pump from damage due...

Page 20: ...ver the Pool Spa valves are turning The pump will NOT shut off when the heater has Cooldown enabled and is either on or in the Heater Cooldown mode Filter Config to view change Filter Name Pool Filter...

Page 21: ...actuators should be connected to the Pro Logic Pressing the POOL SPAbutton on the display keypad will allow the homeowner to alternate between pool and spa operation If Pool and Spa Dual is selected...

Page 22: ...ically locks after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a call back to...

Page 23: ...while the Group is running will make the Group release the alternate setpoint control and revert back to the normal heater setting Any changes that are made at that point will affect the normal heater...

Page 24: ...d dim the patio lights turn on the music etc all at the same time This convenient feature is offered on allAux buttons bothValve buttons and the Lights button TheAqua Plus 16v can be programmed to con...

Reviews: