background image

CAP  

3

BRACKET  

EYEWASH HEAD ASSY 

2

1

4

ALUMINUM SPACER  

5

STERILE ANTIMICROBIAL PRESERVATIVE

 9082

 0310000166

SP131

 0001217418

 SP19

3

6

1

2

3

2

1

5

PARTS BREAKDOWN

STANDBY
"OFF"

POSITION

ACTIVE

"ON"

POSITION

STANDBY
"OFF"

POSITION

ACTIVE

"ON"

POSITION

3X

5

(NOT SUPPLIED, MUST BE ORDERED SEPARATELY)

4

6

0003163925

LABEL, CAP, REFILL  

4

NOT SHOWN

NOT SHOWN

7

BLANKET

*SEE TABLE

7

*

MODELS 7501T/7501T240

MODEL

BLANKET P/N

7501T

7501BL

7501T240

7501BL240

MODEL 7501

(NOT SUPPLIED, MUST BE ORDERED SEPARATELY)

(7501T SHOWN)

APPROVED

DRAWN

PART NUMBER

SCALE:

SHEET

OF

REVISION

DRAWING TYPE:

SIZE:  A

BY

ECN NO.

PAGE

DATE

DATE

ECN:

REVISED PER

CHKD

         Haws Corporation - All Rights Reserved

HAWS    and other trademarks used in these materials are the exclusive property of Haws Corporation.

C

R

MODEL(S)

1455 KLEPPE LANE

SPARKS, NEVADA  89431

(775) 359-4712  FAX (775) 359-7424

E-MAIL:  [email protected]
WEBSITE: WWW.HAWSCO.COM

ITEM

DESCRIPTION

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.

WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.

PART NO.

RTM

04/16/04

16

0002080045

7501/7501T/7501T240

PORTABLE EYEWASH

NA

1

1

MJ

05/29/18

5086

MJ

6 OF 8

PARTS BREAKDOWN

5235

2018

VWC

8

INSPECTION TAG

     SP170

(NOT SUPPLIED, MUST BE

ORDERED SEPARATELY)

8

(NOT SUPPLIED, MUST BE

ORDERED SEPARATELY)

8

Summary of Contents for 7501

Page 1: ...ts except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAW...

Page 2: ...ONNECTIONS reference manual supplied with heating blanket Model 7501T 120VAC 60 Hz 1 38A Requires a three prong outlet and is supplied with a heavy duty 8 foot power cord with GFCI plug Unit is suitable for installation and use in NEMA TYPE 3R areas Must be used with NEMA TYPE 3R certified covered outlet not supplied DURING POTENTIAL FREEZING PERIODS INSURE THAT UNIT IS CONNECTED TO A CONTINUOUS P...

Page 3: ...e lowered position See Installation Drawings pages 7 and 8 of 8 Filled eyewash unit is heavy approximately 80 pounds Wall bracket anchors Quantity 3 not supplied must be strong enough to support the filled eyewash and the weight of a worker leaning on eyewash STEP 4 Fill up to fill line see important note above Requires 8 75 gallons max of water make sure that no debris or contaminants of any kind...

Page 4: ...ome water loss will occur due to natural evaporation process STEP 2 Take proper precautions to help prevent the growth of potentially harmful bacteria in eyewash tanks We recommend either of the following procedures NOTE Disconnect Model 7501T 7501T240 from power source before performing maintenance Procedure A Use suitable Sterile Antimicrobial Preservative Model 9082 to help prevent the growth o...

Page 5: ... reached b Make sure unit is level from front to back and left to right 5 Eyewash flows for less than 15 minutes 5 Fill water level in eyewash tank even with water fill line indicated on side of unit 6 Excessive water loss 6 Check unit for leaks Some loss due to evaporation is normal 7 Heater doesn t turn on Model 7501T 7501T240 7 a Not plugged in or no power to outlet Check GFCI plug 7501T only a...

Page 6: ...BY ECN NO PAGE DATE DATE ECN REVISED PER CHKD Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM ITEM DESCRIPTION THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMP...

Page 7: ...2mm DO NOT EXCEED WATER FILL LINE REFER TO INSTALLATION INSTRUCTIONS IN OPERATION AND MAINTENANCE MANUAL FOR PROPER FILLING PROCEDURES 4 4 MODEL 7501 SHOWN FOR MODELS 7501T 7501T240 WITH HEATED BLANKET SEE SHEET 2 OF 2 FLOOR LINE MOUNTING DETAILS 33 53 838mm 1346mm FLOW PATTERN NOTES 1 WHEN INSTALLING THIS UNIT LOCAL STATE OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS LOCATIONS...

Page 8: ...E SJ SJE SJO SJOO SJT SJTO SJTOO SO SOO ST STO OR STOO AND HAVE A TYPE LETTER SUFFIX OF W W A OR OUTDOOR 10 THE CORD SET SHALL BE MIN 6 FT IN LENGTH AND MIN 18 AWG SIZE FOR FLEXIBLE POWER SUPPLY CORD 11 LISTED STRAIN RELIEF BUSHING SUITABLE FOR CORD SET SIZE AND OUTDOOR USE SHALL BE USED 12 ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE 30mA GFEPD FOR HEAT TRACE ELECTRICAL CURRENTS MAY BE I...