Haws 7501 Nstallation, Operation & Maintenance Instructions Download Page 3

 

 

03/18 

Model 7501/7501T/7501T240 

Page 3 of 8 

 

 

 

 

 

INSTALLATION INSTRUCTIONS 

 

NOTE: 

Instructions apply to all models unless otherwise specified. 

 

STEP 1:

      

Models 7501T/7501T240

: Install the blanket and connect to power source per the 

Installation Manual provided with the heating blanket.  

 

CAUTION – DO NOT ENGERIZE THE HEATING BLANKET POWER SOURCE 
UNTIL THE EYEWASH IS FILLED WITH FLUSHING FLUID (UP TO FILL LINE). 
 
NOTICE: MODEL 7501T240 REQUIRES MINIMUM NEMA/TYPE 4 COMPLIANT 

EQUIPMENT. ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO 
NEC/ CEC CODE USING FLEXIBLE CONDUIT OR CABLE RATED FOR 
NEMA/TYPE 4 – NO RIGID CONNECTION PERMITTED.  

 
STEP 2:

      

Model 7501

: Mount unit to wall utilizing “J” bracket (supplied). Note: ¼” mounting 

hardware not supplied. See Installation Drawing on Page 7 of 8. 

 

Model 7501T/7501T240

: Mount eyewash unit to wall utilizing “J” bracket and three 

aluminum spacers (supplied). Locate one aluminum spacer behind each bolt hole in 
“J” bracket. Note: ¼” mounting hardware is not supplied. See Installation Drawing 
on Page 8 of 8. 
 

STEP 3: 

Make sure portable eyewash unit is level from front to back and left to right before 
securing bracket to wall. Eyewash nozzles should be between 33 inches (83.8 cm) 
and 53 inches (164.6 cm) above the floor when eyewash arm is in the active 
(lowered) position (See Installation Drawings, pages 7 and 8 of 8). 

 

                     Filled eyewash unit is heavy (approximately 80 pounds). Wall bracket anchors 

(Quantity 3 - not supplied) must be strong enough to support the filled eyewash and 
the weight of a worker leaning on eyewash. 

STEP 4:

       Fill up to fill line (see important note above).  Requires 8.75 gallons (max) of water, 

(make sure that no debris or contaminants of any kind are present in the flushing 
fluid). Make sure unit is level from front to back and left to right. If installed as 
indicated, eyewash unit will provide 15-minute duration of flow. 

IMPORTANT – DO NOT FILL PAST WATER FILL LINE AS LEAKAGE WILL 
OCCUR AT THE EYEWASH HEADS. 

 

STEP 5:

 

Model 7501T/7501T240:

 Energize power source and verify operation of heating 

blanket. (Refer to heating blanket Operation Manual)

 

STEP 6:

       Take proper precautions to help prevent the growth of potentially harmful bacteria in 

eyewash tanks. (Refer to Maintenance Instructions) 

IMPORTANT SAFETY NOTICE 

THE NATIONAL ELECTRICAL CODE REQUIRES GROUND-FAULT EQUIPMENT PROTECTION ON EACH 
HEATING CABLE BRANCH CIRCUIT. TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER 
INSTALLATION, CIRCUIT BREAKERS SUCH AS SQUARE D QO-EPD AND QOB-EPD OR EQUIVALENT, WITH 
A 30mA TRIP LEVEL, SHOULD BE USED. PLEASE SUBSTITUTE THESE BREAKERS WHEREVER 
REFERENCE IS MADE TO CONVENTIONAL BREAKERS IN THIS DOCUMENT. ALTERNATIVE DESIGNS 
PROVIDING COMPARABLE LEVELS OF GROUND-FAULT PROTECTION MAY ALSO BE ACCEPTABLE.  

 
 

Summary of Contents for 7501

Page 1: ...ts except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAW...

Page 2: ...ONNECTIONS reference manual supplied with heating blanket Model 7501T 120VAC 60 Hz 1 38A Requires a three prong outlet and is supplied with a heavy duty 8 foot power cord with GFCI plug Unit is suitable for installation and use in NEMA TYPE 3R areas Must be used with NEMA TYPE 3R certified covered outlet not supplied DURING POTENTIAL FREEZING PERIODS INSURE THAT UNIT IS CONNECTED TO A CONTINUOUS P...

Page 3: ...e lowered position See Installation Drawings pages 7 and 8 of 8 Filled eyewash unit is heavy approximately 80 pounds Wall bracket anchors Quantity 3 not supplied must be strong enough to support the filled eyewash and the weight of a worker leaning on eyewash STEP 4 Fill up to fill line see important note above Requires 8 75 gallons max of water make sure that no debris or contaminants of any kind...

Page 4: ...ome water loss will occur due to natural evaporation process STEP 2 Take proper precautions to help prevent the growth of potentially harmful bacteria in eyewash tanks We recommend either of the following procedures NOTE Disconnect Model 7501T 7501T240 from power source before performing maintenance Procedure A Use suitable Sterile Antimicrobial Preservative Model 9082 to help prevent the growth o...

Page 5: ... reached b Make sure unit is level from front to back and left to right 5 Eyewash flows for less than 15 minutes 5 Fill water level in eyewash tank even with water fill line indicated on side of unit 6 Excessive water loss 6 Check unit for leaks Some loss due to evaporation is normal 7 Heater doesn t turn on Model 7501T 7501T240 7 a Not plugged in or no power to outlet Check GFCI plug 7501T only a...

Page 6: ...BY ECN NO PAGE DATE DATE ECN REVISED PER CHKD Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM ITEM DESCRIPTION THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMP...

Page 7: ...2mm DO NOT EXCEED WATER FILL LINE REFER TO INSTALLATION INSTRUCTIONS IN OPERATION AND MAINTENANCE MANUAL FOR PROPER FILLING PROCEDURES 4 4 MODEL 7501 SHOWN FOR MODELS 7501T 7501T240 WITH HEATED BLANKET SEE SHEET 2 OF 2 FLOOR LINE MOUNTING DETAILS 33 53 838mm 1346mm FLOW PATTERN NOTES 1 WHEN INSTALLING THIS UNIT LOCAL STATE OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS LOCATIONS...

Page 8: ...E SJ SJE SJO SJOO SJT SJTO SJTOO SO SOO ST STO OR STOO AND HAVE A TYPE LETTER SUFFIX OF W W A OR OUTDOOR 10 THE CORD SET SHALL BE MIN 6 FT IN LENGTH AND MIN 18 AWG SIZE FOR FLEXIBLE POWER SUPPLY CORD 11 LISTED STRAIN RELIEF BUSHING SUITABLE FOR CORD SET SIZE AND OUTDOOR USE SHALL BE USED 12 ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE 30mA GFEPD FOR HEAT TRACE ELECTRICAL CURRENTS MAY BE I...

Reviews: