Haws 611970358420 Installation, Operation & Maintenance Instructions Manual Download Page 4

10/08 

      Model H1001.8/H1001.8HPS 

Page 2 of 7 

 

RECOMMENDED TOOLS

: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable 

wrench, 10" pipe wrench, 3/32” and 5/32 “ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or 
open end wrench.

 

 

LOCATION OF UNIT:

 The Model H1001.8/H1001.8HPS Cooler is a wheelchair accessible 

drinking facility. The height dimensions shown, meet current ADA requirements. When 
installing this unit, local, state or federal codes should be adhered to. If height other than 
shown is required, then dimensions must be adjusted accordingly. 

 

SUPPLY LINE

: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM) 

flowing pressure. Where sediment or mineral content is a problem, an inlet filter is 
recommended. 

 

PLUMBING CONNECTIONS:

 Inlet is 3/8” O.D. tube. Waste elbow outlet is 1-1/4” O.D. tube. 

 

ELECTRICAL CONNECTIONS

: 115VAC, 60HZ, 4.7 AMPS. Chiller wired direct to incoming 

line, by others. 

 

PARTS LIST 

MODEL PACKAGE 

QUANTITY 

ITEMS INCLUDED 

MTGFR.SM 1 

Mounting 

Frame 

 

#10 Sheet Metal Screws 

HCR8 1 

Chiller 

H1001.8/H1001.8HPS 1 

Bowl 

Assembly 

 

Package supply tubing and two (2) 
fittings 

 1 

Grille 

 

Package of two each-grille attachment 
clips, clip nuts, #10 sheet metal screws 
and 6-32 screws 

 

5/16 -18 retainer nuts  

 

5/16 – 18 x 1 hex head screws 

 

Waste elbow 1-1/4” O.D. 

 

 

INSTALLATION PROCEDURE 

 

GENERAL NOTES:

 

The Model H1001.8/H1001.8HPS Water Cooler assembly requires installation of the mounting 
frame as described in Steps 1 - 2, then mounting the fountain bowl assembly as described in 
Steps 3 - 6, and finally completing chiller water and electrical connections and starting chiller per 
Steps 7 - 11. First check that all required parts are received. 
 

Grounding may cause electrical feedback into the electric drinking fountain causing an 
electrolysis, which creates a metallic taste or an increase in the metal content of the 
water. This condition can be avoided by using dielectric couplings in the assembly. The 
waste line, which is supplied by the installer, should also have a dielectric (plastic) 
coupling to completely isolate the assembly from the building plumbing system. 
 
For all plastic push-in type fitting connections; push tubing into fitting until it bottoms 
out to ensure a watertight connection. To remove, depress the collet and pull tubing out.

 

 
 
 