1. Connect hose using ring nipple connection and banjo bolt with sealing rings or using thread.
✓
max. screw-in depth: 12 mm
✓
max. tightening torque: 7 Nm
Filling with hydraulic uid
1. Open the tank lling screw.
3. Filter fresh hydraulic uid (mineral oil in accordance with DIN 51524). Recommended lter: 10 µm.
4. Pour the ltered hydraulic uid into the tank.
Use the cross marking on the tank to read off the maximum permitted amount. The level of the
hydraulic uid should be within the cross marking.
5. Gently shake the hydraulic power pack so that the air bubbles pass into the tank.
✓
Wait a few hours until all the air bubbles are in the tank.
6. Operate the system with the hydraulic power pack 2-3x with low pressure until there is no more air in
the system.
7. Close the tank lling screw with a tightening torque of 6 + 2 Nm.
8. Vent the hydraulic system using the venting provisions on the consumer.
9. Correctly dispose of the hydraulic uid, hydraulic uid container and any cloths contaminated with
hydraulic uid.