DAMAGE
Hazard for electronic components – property damage
►
To prevent electrostatic discharge, do not touch electronic components and contacts.
►
After switching off the electrical power supply, wait at least 15 minutes for the energy stored in
the capacitors to dissipate.
►
Do not expose components to moisture and an aggressive environment.
►
Always keep any ventilation outlets unobstructed to prevent overheating.
1. Secure the unit against being switched on unintentionally.
2. Wire the motor with the machine controls in accordance with the circuit diagram.
Flow at A and reux at B
Flow at B and reux at A
3. Connect the hydraulic power pack to the electrical power supply.
4. Check the electrical connections after a week’s operating time.
5.3 Hydraulic connection
DAMAGE
Damage from connecting soiled components
Connecting soiled components may cause system failure and irreparable damage.
►
Clean the workspace before connecting the hydraulic system.
►
Clean hydraulic components before connecting the hydraulic system.
►
Only use hydraulic uid of sufcient grade.
DAMAGE
Damage to valves caused by air bubbles
The system to be connected must already be lled with hydraulic uid free of air bubbles before the
hydraulic power pack is connected. Air bubbles in the hydraulic uid cause damage to valves.
Connecting hydraulic hoses
Basic
Protective transport caps have been removed.
Hoses with ring nipple connection Ø 10 mm and banjo bolt G1/8" are used.
1. Connect hose using ring nipple connection and banjo bolt with sealing rings.
✓
sealing rings: copper washers or USIT rings, thin version with washer thickness 1.25 mm
✓
max. screw-in depth: 12 mm
✓
max. tightening torque: 7 Nm
Comfort
Protective transport caps have been removed.
Hoses with ring nipple connection Ø 10 mm and banjo bolt G1/8" or connection using G1/8" thread.
16/27
B 6014 - 07-2021 - 1.0
HAWE Hydraulik SE