background image

Configuration Parameters

Parameter 0x04:
 Name: 

Transient Threshold

 Description: 

Impact detect parameter. 

 

Do not adjust unless advised by Haven Lock.

 Default: 

0x06

 Min: 

0x02

 Max: 

0x12

Parameter 0x03:
 Name: 

Transient Debounce

 Description: 

Impact detect parameter.

 

 Do not adjust unless advised by Haven Lock.

 Default: 

0x02

 Min: 

0x01

 Max: 

0x0A

Parameter 0x02:
 Name: 

Gate Operation Minimum Battery Level%

 Description: 

m battery level at which the gate will activate.

 Default: 

0x0A (10%)

 Min: 

0x00 (0%)

 Max: 

0x32 (50%)

Parameter 0x01:
 Name: 

Heartbeat LED interval

 Description: 

Heartbeat (magenta) LED flash rate in seconds. 

 

Set to zero to disable.

 Default: 

0x00 (disabled)

 Min: 

0x00 (disabled)

 Max: 

0x3C (60 seconds)

Parameter 0xCD:
 Name: 

Lockdown Z vs. Connect Z Product 

 Description: 

This parameter distinguishes the firmware between the Residential Haven Connect Z and the Commercial Lockdown Z. 

 

For Lockdown, this parameter should be set to 0x02. Residential is 0x01. This parameter drives the product ID reported to Z-wave controllers 

 

and enables/disables the capability of wired control inputs often used in commercial installations.  

 Default: 

0x02

 

Lockdown ID: 

0x02

 

Residential ID: 

0x01

Notification Command Class

Notification Name

Notification Name

Manual lock operation

Manual unlock operation

RF lock operation

Power has been applied

Battery is charging

Impact detected

Value

0x01

Battery is full charged

RF unlock operation

Lock jammed

0x02

0x03

0x04

0x0B

0x0A

0x01

0x0C

0x0D

0x0E

0x0F

Type (Value)

Charge battery soon

Charge battery now

Access Control (0x06)

Home Security (0x07)

Power Management (0x08)

All notifications are sent unsolicited.

   HAVEN 

Lockdown

Summary of Contents for HAVEN LOCKDOWN Z

Page 1: ...y Warnings Regulations Warranty Installing Your HAVEN Lockdown Z WAVE Operation LED and Sounds Outward swinging door configuration In swinging door configuration Hardware Accessory Installation Troubl...

Page 2: ...from being forced open when blunt forced is used against the middle section of the door near the outside door handle Any other entry attempt does not fall under the product definition or purpose of HA...

Page 3: ...do not simulate a breach Damage to the unit may affect later functionality Owner is responsible for ensuring unit is operating properly HavenLock Inc expressly disclaims all guarantees whether implie...

Page 4: ...or purposes for which they are not designed or intended 2 which have been subject to alteration abuse misuse negligence or accident 3 which have been improperly stored installed maintained or operated...

Page 5: ...shipment parts can settle and this cycling allows the parts to stretch and maximize their e ectiveness A cycle is simply locking and unlocking the lock via the hand press F and lock gate E Cycling the...

Page 6: ...may be operated with a nger press Pairing button is used for network inclusion network exclusion and defaulting and removing the Haven Lock from the network Device Reset Locally Command Class Reset b...

Page 7: ...still be lowered 3 When charger is plugged in Battery report is sent to the Lifeline One second later Noti cation CC sends Power Management 0x08 event Battery is charging 0x0C Yellow LED ashes every 2...

Page 8: ...K 2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ASSOCIATION 8 4 4 2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_FIRMWARE_UPDATE_MD 3 3 5 Command Class List S...

Page 9: ...Connect Z Product Description This parameter distinguishes the rmware between the Residential Haven Connect Z and the Commercial Lockdown Z For Lockdown this parameter should be set to 0x02 Residentia...

Page 10: ...reset button 3 Yellow 2 Chirp After Reset Unit is locked and detects an impact 3 Yellow 1 Chirp Security noti cation Impact Detection Glossary NWI Network Wide Inclusion NWE Network Wide Exclusion S2...

Page 11: ...10 HAVEN Lockdown OUTWARD SWINGING DOOR CONFIGURATION...

Page 12: ...QUICK START GUIDE 11 IN SWINGING DOOR CONFIGURATION...

Page 13: ...budget for accessories Lock and Unlock control inputs are designed for passive normally open momentary closed switches Switch the control input either Lock or Unlock to gnd common to control the lock...

Page 14: ...s detailed in this guide This guide is simply suggestive and not in any way authoritative Always use your own best judgment Incorrect installation or lack of safety precautions can lead to serious inj...

Page 15: ...m that will walk you through various scenarios involving uncommon door and threshold sizes In most cases this xes the situation but if you still need help contact us How do I turn HAVEN o HAVEN is des...

Page 16: ...months Protect your password You are responsible for your own security HAVEN Connect Z is not a replacement for personal responsibility Do not share your password with anyone you do not trust or know...

Reviews: