Impact Detection
The impact detection function uses an accelerometer that is tuned using parameters 3 and 4 set
in the Configuration Command Class. When the gate is up and transient threshold (parameter 4)
is exceeded, a Home Security (0x07) Notification, event type Impact Detected (0x0A) is sent to
the Lifeline.
Parameter 4:
Name:
Transient Threshold
Description:
Impact detect parameter. Do not adjust unless advised by Haven Lock.
Default:
0x08
Min:
0x02
Max:
0x12
Parameter 3:
Name:
Transient Debounce
Description:
Impact detect parameter. Do not adjust unless advised by Haven Lock.
Default:
0x02
Min:
0x01
Max:
0x0A
Parameter 2:
Name:
Gate Operation Minimum Battery Level%
Description:
m battery level at which the gate will activate.
Default:
0x0A (10%)
Min:
0x00 (0%)
Max:
0x32 (50%)
Parameter 1:
Name:
Heartbeat LED interval
Description:
Heartbeat (magenta) LED flash rate in seconds. Set to zero to disable.
Default:
0x1E (30 seconds)
Min:
0x00 (disabled)
Max:
0x3C (60 seconds)