Hauslane Auto-clean Series Instruction, Use & Care Manual Download Page 3

ELECTRICAL REQUIREMENTS 

Before installation and usage, read all the in­

structions and make sure that the voltage (V) 

and the frequency  (Hz) indicated on the identi­

fication plate (found inside your range hood) 

and all the data inside the appliance are exactly 

the same as the voltage and frequency in your 

home. 

Note: The manufacturer declines all responsibility 

in the event of failure to observe all the accident­

prevention regulations in force which are neces­

sary for normal use and regular operation of the 

electric system. 

This appliance must be grounded. 

This appliance is equipped with a grounding plug cord, 

the plug must be plugged into an outlet that is properly 

installed and grounded. 

Set the electrical power supply within the space covered 

by the decorative flues.  Position the power socket at a 

maximum distance of 30" from where the lead exits from 

the hood. Make sure this does not interface with the 

bracket fastening area or with the decorative flue (where 

the flue attached to the wall). 

Fil the plug into the power socket. Hard wire connection 

is not recommended. 

WARNING 

•  Electrical ground is required on this range hood. 
•  If cold water pipe is interrupted by plastic,  non­

metallic  gaskets or other materials,  DO NOT 

use for grounding. 

•  DO NOT ground to a gas  pipe. 

•  DO NOT have a fuse in the neutral or grounding 

circuit. A fuse in the neutral or grounding circuit 

could result in electrical shock. 

•  Check with a qualified electrician if you are in 

doubt as to whether the range hood is properly 

grounded. 

•  DO NOT use this appliance with any solid state 

fan speed control device. 

•  DO NOT use an extension cord.  If the power 

supply cord is too short,  hire  a qualified electri­

cian to install an outlet near the appliance.

A 120 volt, 60 Hz AC-only electrical supply is re­

quired on a separate  15 amp fused circuit.  A time­

delay fuse or circuit breaker is recommended. The 

fuse must be sized per local codes in accordance 

with the electrical rating of this unit as specified on 

the serial/rating plate located inside the unit near 

the field wiring compartment. THIS UNIT MUST BE 

CONNECTED WITH COPPER WIRE ONLY. Wire 

sizes must conform to the requirements of the Na­

tional Electrical Code,  ANSI/NFPA 70 - latest edi-

lion, and all local codes and ordinances. Wire size 

and connections must conform with the rating of 

the appliance. Copies of the standard listed above 

may be obtained from: 

National Fire Protection Association 

Batterymarch Park 

Quincy, Massachusetts 02269 

For residential use only. 

This appliance should be connected directly to the 

fused disconnect( or circuit breaker) through flexi­

ble, armored or nonmetallic sheathes copper cable. 

Allow some slack in the cable so the appliance can 

be removed if servicing is ever necessary.  A UL 

Listed,  1/2" conduit connector must be provided at 

each and of the power supply cable (at the appli­

ance and at the junction box) 

When making the electrical connection, cut a  1-1/4" 

hole in the wall.  A hole cut through wood must be 

sanded  until smooth.  A hole through  metal must 

have a grommet. 

WARNING -TO REDUCE THE RISK OF FIRE OR 

ELECTRIC SHOCK, do not use this fan with any 

solid-state speed control device. 

WARNING -TO REDUCE THE RISK OF FIRE, 

ELECTRICAL SHOCK, OR INJURY TO PER­

SONS, 

OBSERVE THE FOLLOWING:  Use this 

unit only in the manner intended by the manu­

facturer. If you have any questions, contact the 

manufacturer .. 

Before servicing or cleaning unit, switch power off 

at service panel and lock the service disconnecting 

means to prevent power from being switched on 

accidentally. When the service disconnecting 

means cannot be locked, securely fasten a promi­

nent warning device, such as a tag, to the service 

panel. 

When cutting or drilling into wall or ceiling, do not 

damage electrical wiring and other hidden  utilities. 

CAUTION: For General Ventilating Use Only. DO 

NOT use to exhaust hazardous or explosive 

materials and vapors. 

WARNING 

- TO REDUCE THE 

RISK 

OF FIRE, 

ELECTRICAL SHOCK, OR INJURY TO PER­

SONS, OBSERVE THE FOLLOWING: Installa­

tion work and electrical wiring must be done by 

qualified person(s) in accordance with all appli­

cable codes and standards, including fire-rating 

construction. 

Page:4 

PLAN THE INSTALLATION 

LOCATION PREPARATION 

The hood should be mounted to the bottom of a standard  1. 

wall cabinet. If the hood must be mounted directly to the 

wall, secure the hood to wall studs. 

Use the dimensional drawings below to lay out 

the range hood's mounting holes,  wiring access 

and ductwork by  marking the cabinet bottom and 

drywall  where applicable. 

2.  Make cutouts for wiring and ductwork. 

The hood is connected to a 110-120V AC lighting circuit 

(15 amp) in the circuit breaker or fuse box. 

3.  Install the ductwork so that it is flush to the range 

hood's mounting surface. 

•  Ductwork can be installed vertically or horizontally. 

•  Duct runs should be as short as possible. 
•  Avoid the use of elbows. 

4.  Run two-conductor wire (with ground) from a 

power source to the hood location. Bring approxi­

mately 1/2" of wiring through wiring hole. 

•  Use duct tape at all joints. 
•  Do not use duct smaller than the discharge on the 

hood. 

5.  Drill  four 3/32" diameter  pilot holes at points 

where mounting holes are marked in cabinet 

bottom. 

6.  Insert (4) mounting screws, leaving approximately 

1/4"  of thread exposed. 

NOTE: 

If the bottom of the cabinet is recessed, 

attached wood strips (not included), as shown 

beside, in order to properly install the range 

under the cabinet. The wood strips must be as 

thick as recess. 

Ducting Options (adapters included) 

Option 

� 

Option 

2� 

Option 

� 

6" round duct Vertical Discharge 

3-1/4" x 10" duct Vertical Discharge  3-1/4" x 10" duct Horizontal Discharge 

27" MINIMt  ABOVE 
COOKING  SURFACE 
(29" FOR GAS RANGE) 

Adjustable elbow 

Adapter/Damper 

27" MINIM  M  ABOVE 
COOKING  SURFACE 
(29

FOR GAS RANGE) 

Wall cap 

(29

H

FORGASRANGE) 

Note: We recommend to install the hood at a minimum 27" from an electric range and at 29" from a 

gas range. For optimal performance, the hood should not be installed more than 32" from cooking 

surface. 

Please read the manual before installation. Identifies an instruction which, if not 

followed, might cause serious personal injuries including possibility of death. 

Denotes an instruction which, if not followed, may severely damage the unit and/or 

its components; warranty will be void. 

Page: 5 

Hauslane

267 Wattis Way, San Francisco, CA 94124 
Tel: 1-800-929-0168 E-mail: [email protected] 

Hauslane

267 Wattis Way, San Francisco, CA 94124 
Tel: 1-800-929-0168 E-mail: [email protected] 

Summary of Contents for Auto-clean Series

Page 1: ...INSTRUCTION USE CARE MANUAL UC C190SS 30 UC C395SS 30 UC C395SS_36...

Page 2: ...stallers are recommended because of the larger size and weight of this hood 5 To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not exhaust air into spaces within w...

Page 3: ...ith any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PER SONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manu facturer...

Page 4: ...CAP SUPPLIED ADAPTER DAMPER INSIDE THE HOOD WALL CAP Page 6 Step 1 Hood Preparation 1 Remove the bottom panel of the hood by removing its 5 mounting screws and set aside 2 Unplug the small white conn...

Page 5: ...ocated IN SIDE the back ofthe hood DO NOT remove the gasket 5 Install the adapter with 10 screws previous removed at step 4 Fig A Fig B Fig C Fig D Fig E I Fig F I Page 8 Step 3 Preparing The Range Ho...

Page 6: ...must be in accordance with local codes decrees or national electrical codes If you are unfamiliar with methods of installing electrical wiring secure the services with a qualified electrician Page 10...

Page 7: ...Power Off Switch B Low Speed Switch C Middle Speed Switch D High Speed Switch E Light Switch r r rrr 131 E D C B A Model C395 Premium Auto clean Series A Auto Clean Switch press once will go into the...

Page 8: ...bustible products used for cleaning such as acetone alcohol ether benzol etc are highly explosive and should never be used close to a range Auto cleaning function Only for Model C395 Use the white wat...

Page 9: ...eanv nton 19 20 f r r 11 12 1 3 18 Parts number 1 Top Shutoff plate 2 Gasket 3 Rear Shutoff plate 4 Front plastic panel C190 5 Switch box 6 Left or right motor C190 7 Switch box cover 8 Push button 9...

Reviews: