background image

 

 

Laser warning! 

 

l

 Use extreme caution when the laser beam is switched on 

l

 Do not let the beam aimed direct into people’s eyes 

l

 Be careful not to let the beam reflect into your eyes from a mirror surface 

l

 Do not allow the laser light beam exposed to inflammable or explosive gas 

 
 

Introduction 

 

The non-contact infrared thermometer is designed to be used to measure surface or skin temperature of a 
target object where as by conventional (contact) thermometer seems to be inappropriate (such as moving 
object, surface with live voltage or object which is hard to reach due to harsh environment). 
 
 

Front Panel Legend 

 
 

 

 
 
 

 
 
 
 
 
 

Indicator 

 

1. Low battery symbol 
2. Data hold 
3. Laser sign 
4. °C / °F symbol 
5. Current temperature value  
 

 

 
 
 
 
 
 
 

 

Summary of Contents for 103818

Page 1: ...Infrarot Thermometer Infrared Thermometer Art 103818 Deutsch 2 English 7...

Page 2: ...he Typen verwendet werden Der Betrieb ist nur in trockener Umgebung erlaubt der Kontakt mit Feuchtigkeit ist unbedingt zu vermeiden Eine andere Verwendung als zuvor beschrieben f hrt zur Besch digung...

Page 3: ...ls auf entz ndliche oder explosive Gase Bei Messungen in der N he von Menschen muss der Laserstrahl deaktiviert werden Einf hrung Das Kontaktlose Infrarotthermometer wird benutzt um Temperaturmessunge...

Page 4: ...D vom Gegenstand wird umso gr er wird die Messpunktgr e S des Ger tes Das Verh ltnis zwischen Entfernung und Messpunktgr e ist unten aufgelistet Einen Hei en Fleck Hot Spot Lokalisieren Um einen hei e...

Page 5: ...triebstemperatur 0 50 C 32 122 F l Lagerungstemperatur 20 65 C 4 149 F l Luftfeuchtigkeit 10 90 nicht Kondensierend l Spannungsversorgung 9V Blockbatterie l Produkt Gr e 16 5cm x 9cm x 4cm l Gewicht 1...

Page 6: ...418 0 Fax 02191 8418 840 info haupa com www haupa com Diese Bedienungsanleitung wurde mit gro er Sorgfalt erstellt F r die Richtigkeit und Vollst ndigkeit der Daten Abbildungen und Zeichnungen wird ke...

Page 7: ...only Do not expose it to moisture Any use other than one described above damages the product Moreover this involves dangers such as e g short circuit fire etc No part of the product must be modified...

Page 8: ...inflammable or explosive gas Introduction The non contact infrared thermometer is designed to be used to measure surface or skin temperature of a target object where as by conventional contact thermom...

Page 9: ...outside the area of interest and then scan across with an up and down motion until you located hot spot Emissivity Emissivity is a term used to describe the energy emitting characteristics of material...

Page 10: ...sign is flicking that means the battery is low power please replace the battery then NOTE It is important to turn the meter off before replacing the battery otherwise the thermometer may malfunction...

Page 11: ...e of quality HAUPA GmbH Co KG confirms that the purchased product has been calibrated during the manufacturing process in accordance with the specified inspection instructions All aspects of the activ...

Reviews: