Engine-powered articulated lifts, 12 - 26 m
A
- Safety precautions
3.2.3 - Risk of electrocution
The machine is not electrically insulated and does not offer any protection.
The risks of electrocution are high in the following situations :
• Close to live power lines, consider the movement of the machine and the swaying
of the electric power lines.
• In the event that you were to make accidental contact with a high voltage line, wait for the power to
the line to be switched off before operating the machine.
• During storms.
Never use the machine as a welding earth.
Maintain a minimum safe distance with regard to power lines and electrical devices.
Respect the local rules and the minimum safety distance.
M i n i m u m s a f e t y d i s t a n c e
N.B.-:-T
HIS
TABLE
IS
APPLICABLE
,
EXCEPT
WHEN
THE
LOCAL
REGULATIONS
ARE
MORE
STRICT
.
3.2.4 - Risk of uncontrolled movement and overturning
When in the machine platform, respect the following instructions :
• Before engaging the machine on any indoor or outdoor surface (premises, bridge,
truck, etc.), check that the surface is capable of supporting the load. Check the
maximum value in the technical characteristics (
Section G 1- Main
characteristics).
• During movement reversal from the platform or ground control box, the joysticks or switches must be
stopped in neutral position before reversing the direction of motion.
• Taking note of the overall load dimensions, place the loads in the centre of the platform or distribute
them it a uniform manner.
• Remain vigilant of driving direction reversal on platforms, pavements, etc.. Check the driving direction
with the help of the red or green arrow on the chassis relative to the red and green arrows on the
platform control box.
• Always ensure that the chassis is never driven any less than 1 m(3 ft3 in) m from holes, bumps, tilts,
obstructions, debris and ground coverings that may hide holes and other dangers.
Electric voltage
Minimum safety distance
Mètre
Feet
0 - 300 V
Avoid contact
300 V - 50 kV
3
10
50 - 200 kV
5
15
200 - 350 kV
6
20
350 - 500 kV
8
25
500 - 750 kV
11
35
750 - 1000 kV
14
45
• Do not drive the machine on slopes or tilts beyond the design limits. Check the maximum value in the
technical characteristics(
Section G 1- Main characteristics).