7 Troubleshooting
Error
Cause
Measure for elimination
No ionization
The power pack is
damaged.
Shut the power pack
down immediately and
secure against switching
on.
Signalling lamp flashing
(EN SL LC and EN SL RLC
only)
The ionizing unit is faulty.
Follow work sequence
according to the flow chart
below.
7.1
Replacing fuse
ATTENTION!
Risk of faults!
An incorrect fuse in the power pack may
cause a fault.
Only use fuses of the type indicated.
The unit type and the rated voltage are
indicated on the nameplate.
1.
Disconnect power pack from supply.
2.
Determine and remove the cause for
the blown fuse.
3.
Detach the fuse holder using a
screwdriver and lift out.
4.
Replace fuse and reattach fuse
holder.
Use the following fuse only:
115 V = 0,50 A slow, 5 x 20 mm
230 V = 0,25 A slow, 5 x 20 mm