7 Troubleshooting
15
7
Troubleshooting
NOTE:
If the error cannot be removed
in this way, return the power pack and
ionizing unit for checking to HAUG
GmbH & Co. KG (for address, see
reverse).
Error
Cause
Measure for elimination
Mains failure
Check mains fuse.
Check fuse in power pack.
Check connections in
power pack.
No high voltage
Check high-voltage output
using the Combicheck
(see accessories).
Only applies to types with
thermal cutout:
A short circuit will result in
the power pack
overheating. The installed
thermal cutout will switch
the power pack off.
Replace faulty ionizing unit
and allow the power pack
to cool down for at least
15 min.
No ionization
Only applies to types with
thermal cutout:
Exceeding the permitted
connected length will
result in the power pack
overheating. The installed
thermal cutout will switch
the power pack off.
Check the connected
length and allow the
power pack to cool down
for at least 15 min. For
permissible connected
lengths, refer to page 23.