9 Technical data
23
9.4
Connected lengths
Power Pack
Permissible
connected length
Maximum ionizing
bar length Type A
Maximum ionizing
bar length Type B
01.7780.220,
01.7781.220
5 m
4.7 m
1.4 m
01.7780.200,
01.7780.208,
01.7781.200,
01.7781.208,
01.7830.000,
01.7831.000,
01.7833.000,
01.7833.050,
01.7834.000,
01.7834.050,
01.7835.100,
01.7835.150,
01.7836.100,
01.7836.150
10 m
6 m
3 m
Ionizing
bar
Type A
EI RN, EI RNE, EI RA, EI RAE, EI RNOF, EI RAOF, EI HRN, EI HRA,
EI HRE, EI HRAE, EI PS, EI PRX, EI PRV, EI SL, EIW
Type B
EI VS, EI VSE, EI VSA, EI VSAE, EI VC, EI VCA, EI VCE, EI VCAE,
EI VSOF, EI VSAOF
Ionizing bar Type A:
The maximum cable length (KL) is the permissible connected length (AL) minus the
maximum ionizing bar length (SL).
KL = AL – SL
Ionizing bar Type B:
The maximum cable length (KL) is the permissible connected length (AL) minus 3 x the
maximum ionizing bar length (SL).
KL = AL – (3*SL)