background image

HAUBER-Elektronik GmbH 

 

11 

 

 

 

11.5 

Typical frequency response 

 

10 Hz

–1,000 Hz (standard) 

The frequency response is recorded using a reference sensor. 
• 4 Hz. . . 1,200 Hz acceleration sensor 
 

 

Fig. 2: Typical frequency response 10 Hz

–1,000 Hz 

Frequency in Hz 

Amplification in dB 

 

1 Hz to 1,000 Hz  

The frequency response is recorded using two reference sensors. 
• 1 Hz. . . 10 Hz laser sensor 
• 10 Hz. . . 1,200 Hz acceleration sensor 
 

 

Fig. 3: Typical frequency response 1 Hz

–1,000 Hz 

Frequency in Hz 

Amplification in dB 

 

 

 

 

Summary of Contents for HE103 Series

Page 1: ...ing unit HE103 series Vibration velocity mm s rms ATEX IECEx EACEx Zone 1 2 21 22 Analogue current output 4 20 mA Frequency ranges 10 Hz 1 000 Hz 1 Hz 1 000 Hz Extended rms averaging time T 60 s Manuf...

Page 2: ...or to commissioning the product the instruction manual must be read and understood All rights including translation are reserved Subject to changes Should any question arise please contact HAUBER Elek...

Page 3: ...housing 7 11 Technical data 8 11 1 General data 8 11 2 Electrical data 8 11 3 Permitted operating temperature ranges 9 11 4 Operating range of the vibration monitoring unit 10 11 5 Typical frequency...

Page 4: ...s product which could endanger people machines and systems should it be subject to inappropriate handling non intended use or use and maintenance by insufficiently trained persons Every person employe...

Page 5: ...ons include Vibration monitoring unit Instruction Manual 7 Documents and certificates The following documents and certificates pertaining to type HE103 can be viewed and downloaded here http www haube...

Page 6: ...e resistant casing Ex db Protection through housing Ex tb Application area Atmospheres not at risk of explosion Potentially explosive atmospheres of zones 1 and 21 2 and 22 Marking Type plate Standard...

Page 7: ...lowing conditions must be met for safe operation in potentially explosive atmospheres 10 1 HE103 01 protection pressure resistant housing Electrical data min typ max Supply voltage Un 10 V DC 24 V DC...

Page 8: ...IN ISO 2954 Cross sensitivity 5 Frequency range 10 Hz 1 000 Hz standard 1 Hz 1 000 Hz Calibration point 159 2 Hz and 90 amplitude of the measuring range Maximum acceleration 16 5 g Service life 10 yea...

Page 9: ...es Version Ambient temperature TA Measuring head temperature in the fixing area Standard 40 C to 60 C 40 C to 125 C ATEX IECEx EAC Pressure resistant casing Ex d Protection through housing Ex tb 40 C...

Page 10: ...ibration 2 Fig 1 shows the operating range of the vibration monitoring unit which is limited by the maximum measurable vibration velocity in mm s depending on the frequency in Hz Fig 1 Operating range...

Page 11: ...z 1 200 Hz acceleration sensor Fig 2 Typical frequency response 10 Hz 1 000 Hz 1 Frequency in Hz 2 Amplification in dB 1 Hz to 1 000 Hz The frequency response is recorded using two reference sensors 1...

Page 12: ...d Assembly type Standing vertical or lying horizontal Measurement direction Along the fixing axis Max torque oft the Sensor 8 Nm Max torque of the M12 union nut on the connector 0 4 Nm Weight ca 200 g...

Page 13: ...tronik GmbH 13 11 7 2 Version ATEX IECEx EACEx Ex d Fig 5 Housing with integrated cable All dimensions in mm 1 Cable gland for integrated cable 2 Width A F 24 3 Fixing 4 Measuring direction along the...

Page 14: ...otection through housing Ex tb integrated cable brown Pin 1 10 30 V DC white Pin 2 NC blue Pin 3 4 20 mA black Pin 4 NC PUR sheathed cable approx 6 5 mm 4 pole 0 34 mm NC Not connected The system oper...

Page 15: ...k steps and instructions Screw vibration monitoring unit into the threaded hole of the mounting surface in a friction locked manner using a hex key The tightening torque should be 8 Nm The tightening...

Page 16: ...loops are amongst the most common problems in measurement set ups with sensitive sensor technology These issues arise due to unintentional differences in potential in the electrical circuit between t...

Page 17: ...earth connection can only be ensured for versions with an M12 plug connection For versions with an integrated cable the alternative earthing concept cannot be used 1 Machine earth 2 Evaluation unit me...

Page 18: ...o measured value 4 20 mA No voltage supply Check voltage source and or supply cable Connection cable interrupted Replace connection cable Fuse defective Replace fuse Connection has incorrect polarity...

Page 19: ...ding to local regulations and legislation 17 Accessories Accessories Standard ATEX IECEx Ex d tb Factory calibration certificate x x Evaluation device types 652 and 656 x x HE400 type portable measuri...

Page 20: ...ECEx EACEx Ex d and Ex tb zones 1 2 21 22 Measuring range 8 8 mm s rms only for frequency range 10 Hz available 16 16 mm s rms standard 32 32 mm s rms 64 64 mm s rms 128 128 mm s rms Frequency range 0...

Page 21: ...UBER Elektronik GmbH Fabrikstra e 6 72622 N rtingen Zizishausen Germany declare of our own accord that the product vibration sensor monitoring unit evaluation devices to which this declaration refers...