![Hatteland HM 20T07 MIL User Manual Download Page 61](http://html1.mh-extra.com/html/hatteland/hm-20t07-mil/hm-20t07-mil_user-manual_2107347061.webp)
61
Video Controller Interface Commands
Command Table
IND100103-1
INB100005-8 (Rev 5)
Scalar V Clipping
0xae,
nnn | “+” | “-” |
“r” | “R” |
“?”
Set the vertical clipping size for
non-linear scale mode =
value/increment/decrement
Reset
Query
Scalar vertical clipping
Scalar V Offset
0xaf,
nnn | “+” | “-” |
“r” | “R” |
“?”
Set the vertical offset of the
display window for non-linear
scale mode =
value/increment/decrement
Reset
Query
Scalar vertical offset.
Scalar V stretch
0xb0,
nnn | “+” | “-” |
“r” | “R” |
“?”
Set vertical stretch factor for
non-linear scale mode =
value/increment/decrement
Reset
Query
Scalar vertical stretch.
Select OSD
language
0x95,
n |
“r” | “R” |
“?”
Select language =
English, Danish, Chinese
Reset
Query
“0” – English.
“7” – Danish
“8” – Chinese
Input main select
0x98,
n | “+” | “-” |
“r” | “R” |
“?”
Select input main =
PC or VIDEO or next available
Reset
Query
Main selected.
“0” – PC.
“1” – Composite video.
“2” – S-video.
“3” – Component video.
“4” - DVI
Select menu timeout 0x93,
nn | “+” | “-” |
“r” | “R” |
“?”
Select menu timeout =
value/increment/decrement
Reset
Query
OSD menu timeout value.
“00” – Continuous.
value – Round up to nearest
available step.
if value > max available step, set
it to the max available step.
DPMS Option
0x9f,
“0” | “1” |
“r” | “R” |
“?”
Set power down option =
On/Off
Reset
Query
“0” – Off.
“1” – On.
Display Video
Source Select
0xbc,
“?” |
“0” |
“1”
Query
Name of video source not
displayed.
After switching to a new video
source, the name of the
video source is displayed for 5
seconds.
“0” – disabled.
“1” – enabled.
Auto source select
0x99,
“0” | “1” |
“r” | “R” |
“?”
Set exclusive or priority =
Exclusive/Proirity
Reset
Query
“0” – Exclusive.
“1” – Priority.
“2” – Priority during power up.
GAMMA value
select
0x9d,
n |
“r” | “R”
“?”
Select GAMMA value =
Value
Reset
Query
GAMMA value:
“0” – 1.0, “1” – 1.6
“2” – 2.2, “3” – User Defined
Function
Command
Description
Acknowledge (if enabled)
Summary of Contents for HM 20T07 MIL
Page 7: ...7 INB100005 8 Rev 5 General...
Page 13: ...13 INB100005 8 Rev 5 Installation...
Page 20: ...20 INB100005 8 Rev 5 This page left intentionally blank...
Page 21: ...21 INB100005 8 Rev 5 Operation...
Page 31: ...31 INB100005 8 Rev 5 Specifications...
Page 34: ...34 INB100005 8 Rev 5 This page left intentionally blank...
Page 35: ...35 INB100005 8 Rev 5 Technical Drawings...
Page 38: ...38 INB100005 8 Rev 5 This page left intentionally blank...
Page 39: ...39 INB100005 8 Rev 5 Technical Drawings Accessories...
Page 45: ...45 INB100005 8 Rev 5 Appendixes...
Page 75: ...75 IND100077 24 INB100005 8 Rev 5 Appendix Notes...
Page 77: ...77 General Appendix IND100077 12 INB100005 8 Rev 5...
Page 78: ...hatteland display com...