background image

Form No. TF1946M-1004

13

MAINTENANCE

GENERAL

The Hatco Thermo-Finisher™ warmers are
designed for maximum durability and performance
with minimum maintenance.

WARNING

To avoid any injury, turn the power switch OFF,
unplug the unit from the power source and allow
to cool before performing any maintenance.

NOTE: When the unit is HOT the blower fans will
remain on even when the power switch is turned off.

CLEANING - EXTERIOR

To preserve the bright finish of the unit, it is
recommended that the exterior surfaces be wiped
daily with a damp cloth. Stubborn stains may be
removed with a good stainless steel cleaner or a
non-abrasive cleaner.

CAUTION

Use only non-abrasive cleaners. Abrasive
cleaners could scratch the finish of your
Thermo-Finisher, marring its appearance and
making it susceptible to dirt accumulation.

BLOWER MOTORS

Inspect rear blower motors for food and/or grease
build up and clean off if necessary.

CLEANING - INTERIOR

WIRE PLATE RACK

Remove rack from unit and wash with a mild soap 
and water solution and rinse.

GLASS SURFACES

WARNING

To avoid any injury, turn the power switch OFF,
unplug the unit from the power source and allow
to cool before performing any maintenance.

Upper and lower glass surfaces can be cleaned
after the unit has 

cooled for at least one hour

.

With the wire plate rack removed carefully use a
“grill scraper” or other small hand held scraper and
scrape loose any food debris that has accumulated
on the glass.

CAUTION

Do not remove the glass from the unit for
cleaning purposes. Doing so may cause injury
or damage to the unit.

Remove any stains from the heating surfaces by
wiping off the glass using a moist cloth and ceramic
cooking top cleaner.

WARNING

Unit is not waterproof. DO NOT submerge in
water. Do not operate if it has been submerged
in water. Do not steam clean the interior or flood
with water or liquid solution.

WARNING

To avoid electrical shock or personal injury, do
not steam clean or use excessive water on the
unit.

WARNING

If service is required on this unit, contact your
Authorized Hatco Service Agent, or contact the
Hatco service Department at 800-558-0607 or
414-671-6350; fax 800-690-2966 or International
fax 414-671-3976.

WARNING

This product has no “user” serviceable parts. To
avoid damage to the unit or injury to personnel,
use only Authorized Hatco Service Agents and
Genuine Hatco Replacement Parts when service
is required.

WARNING

Genuine Hatco Replacement Parts are specified
to operate safely in the environments in which
they are used. Some aftermarket or generic
replacement parts do not have the
characteristics that will allow them to operate
safely in Hatco equipment. It is essential to use
Hatco Replacement Parts when repairing Hatco
equipment. Failure to use Hatco Replacement
Parts may subject operators of the equipment to
hazardous electrical voltage, resulting in
electrical shock or burn.

Summary of Contents for Thermo-Finisher TF-1919

Page 1: ...l please bring it to the attention of your supervisor Do not operate this equipment unless you have read and understood the contents of this manual Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio daño Si usted no pued...

Page 2: ...portant Owner Information i Introduction i Important Safety Instructions 1 Model Descriptions 2 All Models 2 TF 1919 2 TF 4619 2 TF 461R 2 TFW 461R 2 Specifications 3 Electrical Rating Chart 3 Plug Configurations 3 Dimensions 4 Installation 5 Unpacking 5 Location 5 Electrical Connections TFW 461R 6 Appliance Legs TFW 461R 6 IMPORTANT OWNER INFORMATION Programming The Unit 7 General 7 Programming C...

Page 3: ...ed in water Do not steam clean the interior or flood with water or liquid solution Form No TF1946M 1004 1 IMPORTANT SAFETY INSTRUCTIONS To avoid electrical shock or personal injury do not steam clean or use excessive water on the unit If service is required on this unit contact your Authorized Hatco Service Agent or contact the Hatco Service Department at 800 558 0607 or 414 671 6350 fax 800 690 2...

Page 4: ...e of the unit An attached cord and plug set is included MODEL TFW 461R The TF 461R features four upper circular elements and one lower rectangular element for even heat distribution from corner to corner Loading and unloading of food is done on the control side of the unit This model must be electrically hard wire connected by a qualified electrician CAUTIONS Do not remove the glass from the unit ...

Page 5: ...ire connected by a qualified electrician This model cannot be used with a cord and plug Model Voltage Watts Amps Phase Plug Configuration Shipping Weight TF 1919 208 4800 23 1 1 NEMA 6 30P 88 lbs 40 kg 240 5000 20 8 1 NEMA 6 30P 88 lbs 40 kg 220 4201 19 1 1 NONE 88 lbs 40 kg 240 5000 20 8 1 NONE 88 lbs 40 kg 380 CE 4513 11 9 1 NONE 88 lbs 40 kg TF 4619 208 7200 20 1 3 NEMA L15 30P 90 lbs 41 kg 240...

Page 6: ... 562 mm 784 mm 432 mm TFW 461R 25 1 2 20 7 8 18 1 2 648 mm 530 mm 470 mm DIMENSIONS Model D Width E Depth F Height TF 1919 13 18 6 3 8 330 mm 457 mm 162 mm TF 4619 13 18 6 3 8 330 mm 457 mm 162 mm TF 461R 13 18 6 3 8 330 mm 457 mm 162 mm TFW 461R 18 13 6 3 8 457 mm 330 mm 162 mm EXTERIOR DIMENSIONS EFFECTIVE FINISHING AREA Figure 3 Dimensions A F D C E B Allow an additional 2 51 mm minimum for pow...

Page 7: ... combustible walls and materials If safe distances are not maintained discoloration or combustion could occur Do not locate unit under shelving or closer than 12 305 mm from the ceiling WARNING On TF 1919 TF 4619 and TF 461R models allow a minimum of 1 25 mm clearance along the sides and back Allow a clearance of 26 660 mm along the front discharge to ensure proper operation and safety WARNING To ...

Page 8: ...nections properly to a minimum of 40 inch pounds 5 A grounding screw is provided near the electrical terminals An equipment grounding conductor must be properly connected to it 6 Replace and secure wire inspection cover APPLIANCE LEGS TFW 461R The TFW 461R Series unit can be installed with or without the 4 1016 mm appliance legs supplied If the appliance is used without the legs the unit must be s...

Page 9: ... units also feature an adjustable Idle mode and adjustable Auto Off mode which allow for additional flexibility NOTE After reading and understanding how to program the unit see PROGRAMMING HINTS and RECOMMENDED FOOD FINISHING GUIDE in this manual for further helpful information NOTE If at anytime during the programming or operation of the unit the display is not reading correctly or the unit is un...

Page 10: ...7D Press the UP or DOWN arrow key until you reach the desired setting Values change by 5 every time an arrow key is pressed Press the ENTER button when you have reached the desired setting 5 Upper Time Value UT The unit will display Figure 7E Press the UP or DOWN arrow key until you reach the desired setting Values change by 1 second every time an arrow key is pressed Holding down an arrow key wil...

Page 11: ...Form No TF1946M 1004 9 PROGRAMMING CONTROLLER 7B LOWER HEAT UPPER HEAT 1 2 3 4 5 7A 7C 7D 7E 7F 7G Figure 7 Programming a Selection ...

Page 12: ... new setting make sure unit is in READY mode and follow these steps 1 Press and hold the DOWN arrow while at the same time press and hold the ENTER button for three seconds The display will show the current programmed Auto Off value Figure 9A 2 To adjust the Auto Off time push either the UP or DOWN arrow until you reach the desired setting Figure 9B The Auto Off mode can be adjusted from 0 indicat...

Page 13: ...Form No TF1946M 1004 11 PROGRAMMING CONTROLLER 8B 8A 8C 9B 9A 9C Figure 8 Programming Idle Mode Figure 9 Programming Auto Off Mode ...

Page 14: ...is ready for product the unit will display Place plate tray with food product on the center of the metal rack when unit is in mode 4 Select one of five preprogrammed finishing cycles Unit will beep and the display will begin counting down the programmed finishing time Note If you make an incorrect selection it can be cancelled by selecting any of the buttons on the Control Panel 5 Finishing is com...

Page 15: ...ll scraper or other small hand held scraper and scrape loose any food debris that has accumulated on the glass CAUTION Do not remove the glass from the unit for cleaning purposes Doing so may cause injury or damage to the unit Remove any stains from the heating surfaces by wiping off the glass using a moist cloth and ceramic cooking top cleaner WARNING Unit is not waterproof DO NOT submerge in wat...

Page 16: ...rdcoated half sheet pan 2 5 cm deep Cheese Sandwich 50 1 minute 100 1 minute 4 sandwiches at once 15 seconds 23 seconds assembled 2 slices of white bread 2 slices of American cheese each PAN USED Hardcoated half sheet pan 2 5 cm deep Chicken Patty 60 4 minutes 40 4 minutes 4 oz breaded 30 seconds 30 seconds refrigerated precooked PAN USED hardcoated half sheet pan Chicken Skewers 85 5 minutes 80 4...

Page 17: ...5 seconds pound patty PAN USED Half sheet pan Mozzarella Sticks 40 5 minutes 50 5 minutes Breaded refrigerated PAN USED Half sheet pan Nachos 75 1 minute 70 1 minute Corn chips topped with shredded cheddar cheese PAN USED Ceramic plate Pizza 12 31 cm Thin Crust 20 4 minutes 20 3 minutes Frozen to thaw or rethermalize PAN USED 12 31 cm pizza screen Pizza 12 31 cm Thin Crust 50 3 minutes 45 2 minute...

Page 18: ... 45 seconds tortillas stuffed with sauteed peppers onions cheddar cheese PAN USED 10 25 cm aluminum pizza screen Tomato Halves Broiled 75 3 minutes 60 3 minutes Lightly seasoned 30 seconds PAN USED Half sheet pan NOTE When testing a menu item not listed above start by dividing the conventional cooking time by three and use that number as your cooking time Set top and bottom heat at 50 and adjust f...

Page 19: ...ED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights lamp warmer heat bulbs glass components Product failure in booster tank fin tube heat exchan...

Page 20: ...es St Louis 314 890 0700 Kaemmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 2515...

Reviews: