INSTALLATION
DRAIN ASSEMBLY MODELS
WARNING
The drain water may reach temperatures in
excess of 200°F (93°C). To avoid any injury or
damage to the unit use appropriate plumbing
materials when installing drain.
For proper drain plumbing installation conforming to
local plumbing codes consult a licensed plumbing
contractor.
Drain Assembly (See Figure 15)
After installing unit in countertop, install the drain
assembly as follows:
NOTE: Approved air gap or other back-flow
prevention device must be installed by plumber if
required.
1. Connect one end of drain pipe (supplied by
others) to 3/4" NPT drain fitting.
2. Connect other end of drain pipe to drain valve,
(supplied by others).
3. Accessible drain valve (supplied by others) must
connect to external drain pipe.
Figure 15. Drain Connection
Drain
Fitting
Form No. HWBM-0906