INSTALLATION

Form No. GRpWSm-0610

8

General

Hatco  Glo-Ray

®

pizza  Warmers  are  shipped  with  most

components  pre-assembled.  Care  should  be  taken  when

unpacking shipping carton to avoid damage to the unit and

components enclosed. 

ELECTRIC  ShOCK  hAzARD:  Unit  is  not  weatherproof.

Locate unit indoors where ambient air temperature is a

minimum of 70°F (21°C).

FIRE hAzARD: Locate unit a minimum of 1″ (25 mm) from

combustible walls and materials. If safe distances are not

maintained, discoloration or combustion could occur.

The  National  Sanitation  Foundation  (NSF)  requires  that

units over 36″ (914 mm) in width or weighing more than 80

lbs.  (36  kg)  either  be  sealed  to  or  raised  above  the

installation surface. If unit cannot be sealed at the point of

use,  4″  (102  mm)  legs  are  included  to  allow  for  proper

cleaning access below unit.

1. Remove the unit from the carton. Two people are required

for this step.

2. Remove the information packet.

NOTE: To prevent delay in obtaining warranty coverage, fill out

and mail in the warranty card to Hatco.

3. Remove tape and protective packaging from all surfaces of

unit.

Do not lay unit on the side with the control panel. Damage

to unit could occur.

4. Install  the  1″  (25  mm)  rubber  feet  or  4″  (102  mm)

adjustable legs. Two people are required for this step.

a. Carefully lay the unit on its side.

b. Install the feet or legs.

To  install  the  1″  (25  mm)

rubber feet:

• Thread a foot stud into the

hole at each corner on the

bottom of the unit. Tighten

securely.

• Slip  a  rubber  foot  over

each foot stud.

To install the 4″ (102 mm) adjustable legs:

• Thread a leg into the hole

at  each  corner  on  the

bottom of the unit. Hand-

tighten the legs until snug.

Do not over-tighten.

c. Return the unit to the upright

position.

NOTE: 4″  (102  mm)  legs  are

adjustable  for  leveling  the

unit. Use a 5/8″ (16 mm) open-end wrench to make

leveling  adjustments  once  the  unit  is  placed  in  final

position.

4″ Leg

Adjustable Tip

Foot

Stud

Rubber

Foot

NOTICE

CAUTION

WARNING

5. Slide each side glass panel into the upper channel, then

lower the panel into the lower channel.

Figure 10. Side Glass panel Installation (GRpWS-XXXXD shown)

6. Install a box stop with sign holder on the customer side of

each shelf.

• Insert  the  tabs  on  the  back  of  the  box  stop  into  the

brackets on the customer side of the shelf.

Figure 11. Box Stop w/Sign Holder Installation (GRpWS-XXXXT shown)

NOTE: Unit must be transported in the upright position.

7. place the unit in the desired location.

• Locate  the  unit  in  an  area  where  the  ambient  air

temperature  is  constant  and  a  minimum  of  70°F 

(21°C). avoid areas that may be subject to active air

movements or currents (i.e., near exhaust fans/hoods

and air conditioning ducts).

• make sure the unit is at the proper counter height in an

area convenient for use.

• make sure the countertop is level and strong enough to

support the weight of the unit and food product.

• make sure all the feet/legs on the bottom of the unit are

positioned securely on the countertop.

Rear view of 

Box Stop

w/Sign Holder

Side

Glass

Panel

Upper Channel

Lower Channel

Summary of Contents for GLO-RAY GRPWS D Series

Page 1: ...nd the contents of this manual please bring it to the attention of your supervisor Keep this manual in a safe location for future reference No opere este equipo al menos que haya le do y comprendido e...

Page 2: ...tion i Important Safety Information 1 Model Designation 2 Model Description 2 Specifications 3 plug Configurations 3 Electrical Rating Charts GRpWS XXXX models 3 Electrical Rating Charts GRpWS XXXXD m...

Page 3: ...configuration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle Turn power switch OFF unplug power cord an...

Page 4: ...pproximately 185 F 85 C Glo Ray pizza Warmers are available in various widths of 24 36 and 48 610 914 1219 mm and in depths of 18 or 24 457 to 610 mm The units are available in single dual triple or q...

Page 5: ...ze and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle WARNING Figure 4 plug Configura...

Page 6: ...g 220 230 CE 1800 1967 8 2 8 6 CEE 7 7 Schuko 175 lbs 79 kg 230 240 CE 1967 2143 8 6 8 9 BS 1363 or aS 3112 175 lbs 79 kg GRpWS 4824T 120 208 240 2574 14 3 NEma L14 20p 227 lbs 103 kg 220 230 CE 2301...

Page 7: ...m 264 mm 816 mm 543 mm GRpWS 4824 46 7 8 24 1 4 10 3 8 44 1 8 21 3 8 1191 mm 616 mm 264 mm 1121 mm 543 mm GRpWS 2418D 23 7 8 20 1 4 22 9 16 20 1 8 15 3 8 606 mm 514 mm 573 mm 511 mm 391 mm GRpWS 3618D...

Page 8: ...16 32 1 8 15 3 8 911 mm 514 mm 754 mm 816 mm 391 mm GRpWS 4818T 47 7 8 20 1 4 29 11 16 44 1 8 15 3 8 1216 mm 514 mm 754 mm 1121 mm 391 mm GRpWS 2424T 23 7 8 26 1 4 30 3 4 20 1 8 21 3 8 606 mm 667 mm...

Page 9: ...mm 514 mm 935 mm 511 mm 391 mm GRpWS 3618Q 35 7 8 20 1 4 36 13 16 32 1 8 15 3 8 1321 mm 514 mm 935 mm 816 mm 391 mm GRpWS 4818Q 47 7 8 20 1 4 36 13 16 44 1 8 15 3 8 1216 mm 514 mm 935 mm 1121 mm 391 m...

Page 10: ...ch corner on the bottom of the unit Tighten securely Slip a rubber foot over each foot stud To install the 4 102 mm adjustable legs Thread a leg into the hole at each corner on the bottom of the unit...

Page 11: ...energize NOTE The POWER On Off switch must be in the On position for the corresponding heated shelf to function WARNING BURN hAzARD Some exterior surfaces on unit will get hot Use caution when touchin...

Page 12: ...nels using a standard glass cleaner WARNING NOTICE Replacing Display Light Bulbs Use only light bulbs that meet or exceed National Sanitation Foundation NSF standards and are specifically designed for...

Page 13: ...low TEmpERaTuRE CONTROL S set too low adjust TEmpERaTuRE CONTROL S to a higher setting Heating element s not working Contact an authorized Hatco Service agent or Hatco for assistance TEmpERaTuRE CONTR...

Page 14: ...ntamination in the event of breakage For 120 and 120 208 240 volt applications use Hatco part number 02 30 081 00 For 200 220 230 and 230 240 volt applications use Hatco part number 02 30 082 00 Tempe...

Page 15: ...OR FITNESS FOR a paRTICuLaR puRpOSE OR paTENT OR OTHER INTELLECTuaL pROpERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SuCH WaRRaNTIES DO NOT COVER Coated incandescent light...

Page 16: ...rney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEy Jay Hill Repair Fairfield 973 575 9145 Service plus Flanders 973 691 6300 NEW yORK acme american...