INSTALLATION
Connecting the Components
Use the following procedure as a guideline for making the
connections between the components of the remote frost top
drop-in shelf system. These connections must be made by
trained and qualified installers and must comply with all local
plumbing and electrical codes. Refer to the SPECIFICATIONS
section and the wiring diagram included with the unit for details
regarding the plumbing and electrical connections.
1. Connect the liquid and suction refrigerant lines between
the condensing unit, the TXV valve, and the frost top
enclosure evaporator coil. Refer to the appropriate
illustration below and the SPECIFICATIONS section for
connection details.
NOTE: The maximum refrigerant line length between the
condensing unit and the evaporator coil is 50 feet (15 m).
NOTE: For refrigerant line connections, use a self-fluxing
brazing compound (example = Sil-Fos 5
®
) at a brazing
temperature range of 1300–1500°F (704–816°C).
Liquid Connection
(1/4″ O.D. tube)
Liquid Connection
(3/8″ O.D. tube)
Condensing
Unit
Frost Top Enclosure
TXV Valve
Suction Connection
(3/8″ O.D. tube)
TXV Bulb
Fasten TXV bulb to
the suction side of
evaporator coil here.
Suction Connection
(3/8″ O.D. tube)
FTBR Model Refrigerant Connections
Liquid Connection
(3/8″ O.D. tube)
Frost Top
Enclosure
TXV Valve
Suction Connection
(3/8″ O.D. tube)
Solenoid Valve
From
Condensin
g
Unit
To Conde
nsing
Unit
FTBX Model Refrigerant Connections
2. Have a qualified electrician make the appropriate electrical
connections to the control panel. Refer to the wiring
diagram for details.
For FTBR Models:
Condensing Unit
Power Input
a. Connect the on-site power
supply through the power
input knockout to the
POWER IN terminal block.
b. Connect power from the
POWER OUT terminal block,
through the power output
knockout, to the power input
on the condensing unit.
c. Connect the temperature
probe wire from the frost top,
through the probe wire inlet,
to the digital temperature
controller.
Power Input
Power Output
(to condensing unit on
FTBR Models or solenoid
valve on FTBX Models)
Temperature Probe
Wire Inlet
Terminal Blocks
Digital Temperature
Controller
Access Cover
Control Panel Connections