background image

FLOW

MAX

Coffee and Tea Brewer

多功能咖啡花茶机

FM2SS-7 Series

Installation and Operating Manual

安装及操作手册

I&W #07.05.255.00

© 2010 Hatco Corporation

Do not operate this equipment unless you have

read and understood the contents of this manual!

Failure to follow the instructions contained in this

manual may result in serious injury or death. This

manual  contains  important  safety  information

concerning the maintenance, use, and operation

of this product. If you’re unable to understand the

contents  of  this  manual,  please  bring  it  to  the

attention of your supervisor. Keep this manual in

a safe location for future reference.

请在认真阅读并理解本手册的内容后再操作本设备!
不按照本手册中的说明操作可能会导致严重的人身伤
亡事故。本手册中包含了有关本产品维护、使用和操
作的重要安全事项。如果您不理解本手册的内容,请
将本手册交给主管人员,以提请其注意。请将本手册
妥善放置,以便参照。

English = p 2

中文 = 第

12 

Register your unit online!

See IMPORTANT OWNER INFORMATION section for details.

Summary of Contents for FM2SS-7 Series

Page 1: ...ctions contained in this manual may result in serious injury or death This manual contains important safety information concerning the maintenance use and operation of this product If you re unable to...

Page 2: ...t for 1 year FLOWMAX Coffee and Tea Brewers are products of extensive research and field testing The materials used were selected for maximum durability attractive appearance and optimum performance E...

Page 3: ...t indoors where ambient air temperature is a minimum of 21 C 70 F Do not steam clean or use excessive water on unit This unit is not jet proof construction Do not use jet clean spray to clean this uni...

Page 4: ...n handles a locking cover an insulated stainless steel tank providing 2 3 7 0 liters 13 40 servings of coffee or tea Interior components include a coffee tea basket a spreader cover and a pumping tube...

Page 5: ...nfiguration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle NOTE The specification label is located on th...

Page 6: ...the unit from the carton 2 Remove the information packet 3 Remove tape and protective packaging from all surfaces of the unit and any accessories 4 Turn the unit upright and place the unit in the des...

Page 7: ...isplay General use the following procedures to operate a FLOWMAX Coffee and Tea Brewer Read all safety messages in the IMPORTANT SAFETy INFORMATION section before operating this equipment BURN hAzARD...

Page 8: ...r and repeat this procedure NOTE If the unit runs dry and overheats while in operation a safety thermostat will shut off the unit When this happens allow the unit to cool and press the thermostat rese...

Page 9: ...ance or cleaning DO NOT submerge or saturate with water Unit is not waterproof Do not operate if unit has been submerged or saturated with water Do not steam clean or use excessive water on unit This...

Page 10: ...OOTING GUIDE English This unit must be serviced by trained and qualified personnel only Service by unqualified personnel may lead to electric shock or burn WARNING ELECTRIC ShOCK hAzARD Turn power swi...

Page 11: ...athed air heating Built In Heated Well Elements HWB and HWBI Series metal sheathed b One 1 year Parts and Labor PLUS Four 4 years Parts Only Warranty on pro rated terms that hatco will explain at Buye...

Page 12: ...7 17 17 17 18 19 19 19 19 20 21 21 Hatco ______________________________________ ____________________________________ ______________________________________ __________________________________ 9 00 6 00...

Page 13: ...FM2SSM_CN 0810 13 2 5 2 5 OFF 21 C 70 F hatco hatco hatco hatco hatco hatco 2 5 hatco hatco 0512 6732 5091 0512 6732 5092...

Page 14: ...FM2SSM_CN 0810 14 FM2SS 7 50 95 C 122 203 F 2 3 7 0 13 40 1829mm 72 FM2SS 7 1 FM2SS 7 2 F M 2 S S 7...

Page 15: ...0810 15 FM2SS 7 230 CE 2600 11 3 BS 1363 CEE 7 7 Schuko China CCC 11 kg 24 3 CEE 7 7 Schuko BS 1363 China CCC AS 3112 A D E B C 4 A B C D E FM2SS 7 256 mm 305 mm 454 mm 175 mm 175 mm 10 1 8 12 17 7 8...

Page 16: ...FM2SSM_CN 0810 16 21 C 70 F 1 2 3 4 21 C 70 F 5 FM2SS 7...

Page 17: ...FM2SSM_CN 0810 17 5 FM2SS 7 1 2 2 0 5 2 0 5 3 2 3 7 0 13 40 0 24 5 4 5 6 7 8 9 10 11 a c1 95 C 203 F 87 C 189 F c2 82 C 180 F 85 C 185 F c3 76 C 169 F 79 C 174 F b 1 2 3 50 95 C 122 203 F...

Page 18: ...201 F t3 86 C 187 F 88 C 190 F t4 95 C 203 F 94 C 201 F 12 25 30 13 0 24 5 1 2 3 2 3 7 0 13 40 0 24 5 4 5 6 7 50 95 C 122 203 F 8 25 30 13 2 3 l 228 256 16 18 1 20 3 5 l 256 299 18 21 1 26 4 6 l 299...

Page 19: ...FM2SSM_CN 0810 19 4 5 1 1 3 2 75 25 3 4 5 95 C 203 F 6 25 30 7 8 9 3 8 10 OFF hATCO hATCO hATCO hATCO hatco hatco 0512 6732 5091 0512 6732 5092 1 2 3...

Page 20: ...FM2SSM_CN 0810 20 OFF HATCO 2 5 1 2 3 4 5 6 e e3 e HATCO...

Page 21: ...TCO 1 HATCO 18 HATCO HATCO a 1 1 HWB HWBI b 1 4 hATCO 3CS FR c 1 9 d 90 2 HATCO HATCO HATCO HATCO HATCO HATCO HATCO HATCO HATCO HATCO 1 HATCO 18 hatco Hatco Hatco Hatco HATCO HATCO 0512 6732 5091 HATC...

Page 22: ...Form No FM2SSM_CN 0810 22 NOTES English...

Page 23: ...Form No FM2SSM_CN 0810 23 NOTES English...

Page 24: ...4121 Fax 852 2991 4181 hongkong hatcocorp com 07 04 546 00 FM2SSM_CN 0810 24 2010 8 HATCO CORPORATION P O Box 340500 Milwaukee WI 53234 0500 U S A Telephone 414 671 6350 International Fax 414 671 397...

Reviews: