background image

Form No. FSDM-0119

15

English

Display Racks for FSD

Several display racks are available to “customize” FSD models to specific foodservice operations.

3-Tier Circle Rack*

Rack Openings: 4-5/8″ (117 mm) 

5-Shelf Multi-Purpose Rack

Shelf 1 Rack Opening: 2-1/2″ (63 mm)

NOTE: Shelf 1 is the bottom shelf.

Shelves 2, 3, & 4 Rack Opening: 2-3/4″ (69 mm)

Shelves 2, 3, & 4 are removable.

3-Tier Pan Rack

Rack Openings: 3-1/2″ (89 mm)

*Racks designed for use

with motorized display.

Display Racks for FSDT

Several display racks are available to “customize” FSDT models to specific foodservice operations.

4-Tier Circle Rack*

Rack Openings:

4-5/8″ (117 mm)

3-Tier Pretzel Tree*

Rack Openings: 

5-7/8″ (149 mm)

7-Shelf Multi-Purpose Rack

Shelves 1 & 5 Rack Opening:

2-1/2″ (63 mm). 

NOTE: Shelf 1 is the bottom shelf.

Shelves 2, 3, 4 & 6 Rack Openings: 

2-3/4″ (69 mm)

Shelves 2, 3, 4, 6, & 7 are removable.

4-Tier Pan Rack

Rack Openings:

3-1/2″ (89 mm)

3-Shelf Angle Rack

Rack Openings: 3-1/2″ (89 mm)

Middle shelf is removable.

Rack shelves slant

at 15° angle.

*Racks designed

for use with

motorized display.

5-Tier Circle Rack*

Rack Openings:

3-7/8″ (98 mm)

TROUBLESHOOTING GUIDE

OPTIONS AND ACCESSORIES

Error Codes

The following error codes may appear on the digital display to 

indicate an error in the operating condition of the unit.

LO H20

 = Low water probe does not detect water. Refill water 

reservoir — refer to instructions in OPERATION 

section of this manual.

E1

 = Air temperature sensor malfunctioning. Contact an 

Authorized Hatco Service Agent or Hatco for assistance.

E2

 =  Humidity temperature sensor malfunctioning. Contact an 

Authorized Hatco Service Agent or Hatco for assistance.

dE-L

 = Water reservoir needs de-liming. Refer to the 

“Removing Lime and Mineral Deposits” procedure 

in the MAINTENANCE section of this manual to 

clean and de-lime the water reservoir. Refer to the 

“Setting the De-liming Detection Mode” procedure in 

the MAINTENANCE section of this manual to set the  

de-liming detection mode “on” or “off.” Contact 

Authorized Service Agent or Hatco for assistance.

Troubleshooting Questions?

If you continue to have problems resolving an issue, please 

contact the nearest Authorized Hatco Service Agency or Hatco 

for assistance. To locate the nearest Service Agency, log onto 

the Hatco website at 

www.hatcocorp.com, 

select the 

Support

 

pull-down menu, and click on “Find A Service Agent”; or contact 

the 

Hatco Parts and Service Team

 at:

Telephone: 800-558-0607 or 414-671-6350
e-mail: [email protected]

Summary of Contents for FLAV-R-SAVOR FSD-1

Page 1: ...rte Este manual contiene importante informaci n sobre seguridad concerniente al mantenimiento uso y operaci n de este producto Si usted no puede entender el contenido de este manual por favor pregunte...

Page 2: ...d thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Specifications 5 Dimensions 5 Plug Configurations 5 E...

Page 3: ...ts i e near exhaust fans hoods air conditioning ducts and exterior doors Clean unit daily to avoid malfunctions and maintain sanitary operation WARNING ELECTRIC SHOCK HAZARD Plug unit into a properly...

Page 4: ...he FSDT 1 is a single door model with a revolving display motor like the FSD 1 but is 5 127 mm taller On each model the rotating rack stops automatically when the door is opened For details on differe...

Page 5: ...ding to the applications WARNING ELECTRIC SHOCK HAZARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match c...

Page 6: ...15P 112 lbs 51 kg FSD 2X no humidity 1089 9 1 Model Voltage Hertz Watts Amps Plug Configuration Shipping Weight FSDT 1 with humidity 120 60 1414 11 8 NEMA 5 15P 120 lbs 54 kg FSDT 1 no humidity 1089...

Page 7: ...N Locate unit at the proper counter height in an area that is convenient for use The location should be level to prevent the unit or its contents from falling accidentally and strong enough to support...

Page 8: ...ve the fluorescent lamp cover to allow access to the hinge bracket striker plate hardware if necessary 5 Remove the screws holding the hinges to the cabinet 6 Remove the screws from the striker plates...

Page 9: ...re to install the proximity switch in the orientation shown below for the specific installation location Incorrect orientation will result in malfunction of the proximity switch 5 Remove the screw and...

Page 10: ...the water reservoir with clean water To fill the reservoir a Lift up the WATER FILL cup cover and pull forward b Slowly pour water into the cup until LO H2O stops flashing on the cabinet temperature d...

Page 11: ...mode NOTE Temperature and humidity settings may vary depending upon product make up and consistency The CABINET TEMPERATURE display shows the lowest temperature point inside the cabinet not the produc...

Page 12: ...emoved with a good non abrasive cleaner Clean hard to reach areas using a small brush and mild soap NOTE Both the rotating display rack and the stationary rack are removable for cleaning if necessary...

Page 13: ...d of time such as the end of the day 1 Turn off the unit unplug the power cord and allow the unit to cool 2 After the unit has cooled down perform the Draining the Water Reservoir procedure in this se...

Page 14: ...g too much humidity inside the cabinet causing steam inside unit Humidity control is set too high Adjust the humidity control to a lower setting Air temperature is set too low Adjust the temperature t...

Page 15: ...SSORIES Error Codes The following error codes may appear on the digital display to indicate an error in the operating condition of the unit LO H20 Low water probe does not detect water Refill water re...

Page 16: ...air pockets or bubbles behind the sticker can be removed by rubbing gently with a soft cloth from the center towards the outer edges Decal Decal Installation Decorative Kits Several decorative kits ar...

Page 17: ...s 2 Place the printed sign in the holder and slide the protective acrylic window over the sign 7 1 2 191 mm Sign Holder 3 1 4 83 mm Sign Holder Screw Merchandising Display Sign Holder 3 1 2 83 mm heig...

Page 18: ...OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp...

Page 19: ...e et de performance optimum Chaque appareil est minutieusement inspect et test avant exp dition Informations Importantes pour le Propri taire 19 Introduction 19 Consignes de S curit Importantes 20 D s...

Page 20: ...ER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresse...

Page 21: ...l appareil pour viter les dysfonctionnements et maintenir l hygi ne AVIS N installez pas l appareil dans un endroit pr sentant des d placements d air excessifs vitez les zones pouvant tre soumises des...

Page 22: ...ur chaque mod le le pr sentoir rotatif s arr te automatiquement l ouverture de la porte Pour des d tails sur les diff rentes options de grille voir la section OPTIONS ET ACCESSOIRES Mod le FSD 1 NOTA...

Page 23: ...fournies en fonction de l application AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects...

Page 24: ...SDT 2X sans humidit 1089 9 1 Mod le Tension Puissance Intensit Amps Configuration de Fiches Poids d embarquement FSD 1 avec humidit 120 60 1414 11 8 NEMA 5 15P 51 kg 113 lbs FSD 1 sans humidit 1089 9...

Page 25: ...reil n est pas l preuve des intemp ries Placer l appareil l int rieur une temp rature ambiante de 21 C minimum DANGER D INCENDIE Placer l appareil un minimum de 25 mm des parois et mati res combustibl...

Page 26: ...lle nylon 3 R installer l axe de charni re sup rieur 4 Retirer le couvercle de la lampe fluorescente pour acc der au support de charni re la plaque de but e si n cessaire 5 Enlever les vis qui fixent...

Page 27: ...ssurez vous d installer le commutateur de proximit comme indiqu ci dessous en fonction du lieu d installation Un mauvais placement peut entra ner un dysfonctionnement du commutateur de proximit 5 Reti...

Page 28: ...lever le couvercle du godet de remplissage d eau et le tirer vers l avant b Verser lentement l eau dans le godet jusqu ce que LO H2O cesse de clignoter sur l affichage de temp rature de l armoire REMA...

Page 29: ...e temp rature et d humidit peuvent varier en fonction du mode de pr paration et de la consistance des produits L indicateur de temp rature affiche la temp rature la plus basse l int rieur de l armoire...

Page 30: ...on nettoyant non abrasif Nettoyer les zones difficiles d acc s avec une petite brosse et du savon doux NOTA Le pr sentoir rotatif et le pr sentoir fixe sont amovibles pour nettoyage au besoin Pour les...

Page 31: ...n de tartre et de s diments ne sont pas couvertes par la garantie limination des d p ts de tartre et de calcaire Proc der comme suit pour le nettoyage et la d tartrage p riodiques du r servoir d eau d...

Page 32: ...le haut de la bande lumineuse DEL dans le logement DEL 7 Ins rer la bande lumineuse DEL dans les clips pour la maintenir Clip DEL Logement DEL Bande lumineuse DEL Connecteur Remplacer une bande lumine...

Page 33: ...ne produit pas d air chaud dans l armoire Disjoncteur ouvert Contactez votre agent de maintenance agr ou Hatco pour assistance V rifier si la tension correcte est fournie l l ment chauffant Moteur de...

Page 34: ...ur Find A Service Agent trouver un agent d entretien ou contactez l quipe d entretien et de pi ces d tach es de Hatco Num ro de t l phone 800 558 0607 or 414 671 6350 Courriel support hatcocorp com Pi...

Page 35: ...SD 2CB FSD 1CB FSD SQB FSD CTLH FSD CUSH NOTA Assurez vous d indiquer la couleur au moment de commander Kits d coratifs Accouplement de pr sentoir sans moteur L accouplement de pr sentoir sans moteur...

Page 36: ...7 8 Pr sentoir Polyvalent 7 Niveaux Les niveaux 1 et 5 Ouvertures de pr sentoir 63 mm 2 1 2 NOTA Le niveau 1 est le niveau inf rieur Les niveaux 2 3 4 et 6 Ouvertures de pr sentoir 69 mm 2 3 4 Les niv...

Page 37: ...TRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairage incandescence e...

Page 38: ...Form No FSDM 0119 38 English NOTES...

Page 39: ...Form No FSDM 0119 39 English NOTES...

Page 40: ...aemmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JE...

Reviews: