background image

SPECIFICATIONS

Form No. FS2HACM-0608

3

Model

Voltage

Hertz

Watts

Amps

Plug Configuration Shipping Weight

FS2HAC-2PT

120/208

60

2978

12.4

NEMA L14-20P

165 lbs. (75 kg)

120/240

60

2978

12.4

NEMA L14-20P

165 lbs. (75 kg)

220

60

2924

13.3

NEMA 6-15P

165 lbs. (75 kg)

240

60

2948

12.3

NEMA 6-15P

165 lbs. (75 kg)

220-230 (CE)

50

2924–3196 13.3–13.9

CEE 7/7 Schuko

165 lbs. (75 kg)

230-240 (CE)

50

2708–2948 11.8–12.3

BS-1363

165 lbs. (75 kg)

FS2HAC-4PT

120/208

60

3378

14.1

NEMA L14-20P

190 lbs. (86 kg)

120/240

60

3378

14.1

NEMA L14-20P

190 lbs. (86 kg)

220

60

3324

15.1

NEMA 6-20P

190 lbs. (86 kg)

240

60

3348

14.0

NEMA 6-20P

190 lbs. (86 kg)

220-230 (CE)

50

3324–3632 15.1–15.8

CEE 7/7 Schuko

190 lbs. (86 kg)

230-240 (CE)

50

3076–3348 13.4–14.0

None

190 lbs. (86 kg)

Electrical Rating Chart

NOTE: Shipping weight includes packaging.

Plug Configurations

Units are supplied from the factory with an electrical
cord and plug installed (plugs are supplied
according to the applications). Some export units
may require field installation of the proper plug.

ELECTRIC SHOCK HAZARD:

• Plug unit into a properly grounded electrical

outlet of the correct voltage, size, and plug
configuration. If the plug and receptacle do
not match, contact a qualified electrician to
determine and install the proper voltage and
size electrical outlet.

• Units supplied without an electrical plug

require field installation of the proper plug.
Plug must be properly grounded and of the
correct voltage, size, and configuration for
the electrical specifications of the unit.
Contact a qualified electrician to determine
and install the proper electrical plug.

WARNING

Figure 4. Plug Configurations

NOTE: Receptacle not supplied by Hatco.

NEMA L14-20P

CEE 7/7 Schuko

BS-1363

NEMA 6-15P

NEMA 6-20P

The shaded areas contain electrical information for

Export models only.

Summary of Contents for FLAV-R-SAVOR FS2HAC Series

Page 1: ... una localización segura para la referencia futura 2008 Hatco Corporation Do not operate this equipment unless you have read and understood the contents of this manual Failure to follow the instructions contained in this manual may result in serious injury or death This manual contains important safety information concerning the maintenance use and operation of this product If you re unable to und...

Page 2: ...abinets are products of extensive research and field testing The materials used were selected for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information i Introduction i Important Safety Information 1 Model Designation 2 Model Description 2 All Models 2 Specifications 3 Plug Configurations 3 Elect...

Page 3: ...ed electrician to determine and install the proper voltage and size electrical outlet Units supplied without an electrical plug require field installation of the proper plug Plug must be properly grounded and of the correct voltage size and configuration for the electrical specifications of the unit Contact a qualified electrician to determine and install the proper electrical plug Turn the power ...

Page 4: ...ng on the configuration The temperature range of the Flav R Savor Heated Air Curtain Cabinets is 80 200 F 27 93 C FS2HAC 2PT Model The FS2HAC 2PT is a two pan pass through style unit that allows for food product access from either side The unit is capable of holding two full size sheet pans Figure 2 FS2HAC 2PT Model FS2HAC 4PT Model The FS2HAC 4PT is a four pan pass through style unit that allows ...

Page 5: ...Plug Configurations Units are supplied from the factory with an electrical cord and plug installed plugs are supplied according to the applications Some export units may require field installation of the proper plug ELECTRIC SHOCK HAZARD Plug unit into a properly grounded electrical outlet of the correct voltage size and plug configuration If the plug and receptacle do not match contact a qualifie...

Page 6: ... 464 mm 102 mm FS2HAC 4PT 24 1 8 39 1 8 33 26 1 4 4 613 mm 994 mm 838 mm 667 mm 102 mm SPECIFICATIONS 4 Form No FS2HACM 0608 Dimensions C A Front View Side View D E B Cabinet Openings FS2HAC 2PT 18 1 4 W x 8 1 4 H 464 x 235 mm FS2HAC 4PT 18 1 4 W x 16 1 4 H 464 x 438 mm Figure 5 Dimensions FS2HAC 4PT shown ...

Page 7: ...tip for leveling General The Flav R Savor Heated Air Curtain Cabinets are shipped with most components installed and ready for operation The following installation instructions must be performed before plugging in and operating the cabinet FIRE HAZARD Locate the unit a minimum of 1 25 mm from combustible walls and materials If safe distances are not maintained discoloration or combustion could occ...

Page 8: ...exterior surfaces on the unit will get hot Use caution when touching these areas 4 Press the AIR TEMPERATURE key twice to check the setpoint temperature setting The CABINET TEMPERATURE display will return automatically to operational mode showing the current unit temperature in a few seconds If the setpoint temperature is incorrect or a different temperature is required refer to the Setting the Ai...

Page 9: ...tops on the shelves When one sheet pan is being used Position the sheet pan on the bottom shelf Reach in with tongs and serve the food product Do not pull out the sheet pan Figure 9 FS2HAC 2PT with One Pan Pan Stops Bottom Position FS2HAC 4PT Model The FS2HAC 4PT model has a four sheet pan capacity When referring to shelf positions in the unit the lowest shelf is shelf 1 and the highest shelf is s...

Page 10: ...with a clean sanitized cloth Hard to reach areas may be cleaned using a small brush and mild soap Stubborn stains may be removed with a good stainless steel cleaner or a non abrasive cleaner Use non abrasive cleaners only Abrasive cleaners could scratch the finish of your unit marring its appearance and making it susceptible to soil accumulation NOTICE WARNING This unit has no user serviceable par...

Page 11: ...all times with one on lowest shelf and the other two shelves above Adjust temperature setpoint to the proper setting Unit not allowed to reach setpoint temperature Allow unit 30 to 60 minutes to reach setpoint temperature Place a pan on the lowest shelf Move the Power ON OFF switch to the ON position Plug unit into the proper power supply Reset the circuit breaker Symptom Probable Cause Corrective...

Page 12: ...t sheet pans behind pan stops on each side No sheet pans or not enough sheet pans in cabinet For two pan models Put two pans in cabinet at startup Keep at least one pan in cabinet on lowest shelf at all times For four pan models Put four pans in cabinet at startup Keep at least two pans in cabinet at all times with one on lowest shelf and the other two shelves above Symptom Probable Cause Correcti...

Page 13: ...ACCESSORIES Form No FS2HACM 0608 11 Pans Aluminum sheet pans are available directly from Hatco Order Hatco stock item 18 Sheet Pan 18 x 26 457 mm x 660 mm Figure 12 Full Size 18 Sheet Pan ...

Page 14: ...ED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights decorative heat lamp bulbs coated halogen light bulbs halogen heat lamp bulbs heated glass shelves glas...

Page 15: ... Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 2515 Appliance Installation Buffalo 716...

Reviews: