TROUBLESHOOTING GUIDE
Form No. FS2HACM-0608
9
Switch is not illuminated
and no heat.
Switch is illuminated but
unit has low or no heat.
Power ON/OFF switch in the OFF
position.
Unit not plugged in.
Circuit breaker tripped.
Temperature setpoint is too low.
No sheet pan in lowest shelf.
No sheet pans or not enough sheet
pans in cabinet.
Defective component.
Contact Authorized Service
Agent or Hatco for assistance.
For two pan models: Put two
pans in cabinet at startup. Keep
at least one pan in cabinet on
lowest shelf at all times.
For four pan models: Put four
pans in cabinet at startup. Keep
at least two pans in cabinet at
all times with one on lowest
shelf and the other two shelves
above.
Adjust temperature setpoint to
the proper setting.
Unit not allowed to reach setpoint
temperature.
Allow unit 30 to 60 minutes to
reach setpoint temperature.
Place a pan on the lowest shelf.
Move the Power ON/OFF
switch to the ON position.
Plug unit into the proper power
supply.
Reset the circuit breaker.
Symptom
Probable Cause
Corrective Action
Defective component.
Contact Authorized Service
Agent or Hatco for assistance.