12
Installation of Star Wheel Moisture Sensors
– 700BBHD
1. Locate the two star wheel moisture sensors (030-4642U and 030-4642UE) and star wheel
reinforcement brackets (001-4644BBHD) show on the right and parts bag (E)
2. The two pre-drilled mounting holes for the star wheels are located past the knotters on the
side of the top support bar running the length of the bale chute (Figure 1).
3. Position the star wheel mounting holes and mark the width of the star wheel 4
” (112mm).
As well as the depth of the star wheel
of 2” (50mm). This piece will need to be removed
from the baler bracket in order for star wheel to fit flush with baler bracket (Figure 2). After
cutting touch up with paint to prevent rusting.
4. Mount star wheel with two position plug on right side of baler when looking at the back. Mount star wheel
with six position plug to left side or ladder side of baler. Use hardware from parts bag (E) to mount
5. Position reinforcement brackets (001-4644BHD) around the star wheel. Shown mounted in Figure 3.
Repeat mounting the star wheel and installation of the reinforcement bracket on the right side of baler.
Used suppled 3/8” x 3/4” Carriage bolts and flange nuts to secure
6. Attach harness (006-7307EM2) wires to star wheels and route to (IPM) module and connect to the square
plug on it.
Figure 3
001-4644BBHD
Figure 2
Figure 1