background image

 

 

 

 
 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

 
 

77E-INST/OPR 

– Imp&Metric 

4/21 

Installation/Operation Manual 

 

Model 77E 

 

Economy Microwave Moisture Bale Chute System 

 

 

Summary of Contents for 770

Page 1: ...1 77E INST OPR Imp Metric 4 21 Installation Operation Manual Model 77E Economy Microwave Moisture Bale Chute System ...

Page 2: ... application preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 2004 108 EC on the Electromagnetic compatability The application of preservatives for hay Harvest Tec system will be turned on after being installed on a farm press has been declard in conformity w...

Page 3: ...er Display Integration AGCO 21 2200 series Baler Display Integration AGCO 2370UHD Baler Display Integration Case LB334 434 New Holland Big Baler Series Baler Display Integration Case LB436HD New Holland Big Baler 340 1290HD Baler Display Integration John Deere 330 340 7 26 7 7 10 11 12 13 19 20 22 23 26 Moisture System Setup 26 27 Common Questions 28 Troubleshooting 29 Pin Outs 30 32 Parts Breakdo...

Page 4: ... the system please view the Parts Breakdowns in the back of this manual and contact your local authorized dealer to order the parts Tools Needed Standard wrench set Electric drill and bits Side cutter Standard nut driver set Standard socket set System Requirements for integration into baler display CNH Balers The Baler Control Module BCM must have Version 4 2 0 0 or higher AGCO Balers The Baler Pr...

Page 5: ...interfere with microwave sensors Attach the microwave moisture sensors to each mounting bracket Sensor 006 4641MTX will be mounted on the left side of the bale chute figure 4 Sensor 006 4641MRX will be mounted on the right side figure 5 Mount the sensors with the wire connection port toward the baler Locate the MWM wiring harness 006 7640MWL in the kit Start by locating the connector with the whit...

Page 6: ...g See wiring schematics for attaching tractor power harness 006 764IC to battery power 2 display options of microwave moisture 1 Readings integrated into baler virtual terminal for AGCO 21 2200 series Krone balers with CCi1200 monitor CASE 334 434 434HD models New Holland Big Baler series model and John Deere 330 340 with use of baler integration harness 006 7670A to the in cab diagnostic port 2 R...

Page 7: ...ure sensor Tablets can be used in addition to integrated baler VT display Made for iPad 3rd generation minimum or Android Tablet Does not work with Amazon Fire Required to be running the most current operating system or one version previous iPad is a trademark of Apple Inc registered in the U S and other countries Baler Display Integration AGCO 21 2200 series balers The ISOBUS Monitor utilizes a c...

Page 8: ...ve System select the fourth icon down on the right screen menu the wrench icon arrow B The service screen displayed below will appear Here you can see the Version of Software for your baler which should be 3 30 or higher to enable working with the 77E Select the icon arrow C located at the bottom of the right selection menu to move to the next options menu Then select the A B icon arrow D on the r...

Page 9: ...the thumb wheel to scroll and select the Harvest Tec Option arrow F Press the scroll wheel to open the drop down menu Select the green check mark to turn the Harvest Tec option ON arrow G Then select the Baler Run Screen button arrow H to save the setting and proceed to the baler run screen E F H G ...

Page 10: ...ow with a red background The moisture information is denoted by a rain droplet for instantaneous and a rain drop with a back arrow above for the last bale average moisture These values are separated by a slash NOTE When the preservative sprayer icon is RED the preservative system is not in a run mode Auto or Manual When the system is in a run mode the icon will be GREEN The HT Preservative and Moi...

Page 11: ...em Off These four containers can be configured by the operator In the selectable list are the items for your system They are Current moisture and average moisture When moisture is above your alarm setpoint it will show the moisture value with a red background Background turns red when system is on main work screen The icon will blink when the system is paused ...

Page 12: ... seen below The numbered and colored soft keys on the right side 1 6 correlate to the selection options on the screen For example Manual Mode is PURPLE this correlates to the PURPLE number 3 soft key option on the right side Arrow M So to enter Manual Mode the scroll wheel can be used to select the button or the soft key next to the PURPLE number 3 option can be pressed To return to the baler work...

Page 13: ...creen options to make selections Selections are made by finding the desired selection and pressing the touch screen icon All buttons are labeled and color coded When the 77E Microwave is connected thru the baler and powered on the first time it is necessary to load the object pools to the Virtual Terminal VT ...

Page 14: ...n loaded and Icon 1 disappears from the upper left corner of the display press the NEXT IMPLEMENT button 2 and verify that the 77E object pools appear on the Virtual Terminal After verifying that the 77E object pool is loaded and the operating screens are displayed on the VT press the NEXT IMPLEMENT button 3 to return to the baler work screen page Press the bottom button of the Menu Bar with the d...

Page 15: ...on 4 2 0 0 or higher proceed to configuring the baler for the 77E system by pressing the MACHINE SETUP button 6 Once the MACHINE SETUP icon has been selected the Machine Setup page will appear and the icon will be backlit in orange Press the MACHINE SETUP icon 7 again to go to the second page of the Machine Setup The second page of the Machine setup is identified by the three gray buttons in the M...

Page 16: ...Mode screen select the area under Moisture 10 Note that the box below Moisture will likely be the default NOT INSTALLED Select the proper configuration setting from the pop up menu 11 based on the configuration of your 77E system This configuration setting allows the baler to properly display the information it is receiving from the 77E system on the baler working screen Select DCP 10 11 9 ...

Page 17: ... scroll down thru the Menu Bar until you reach the SCREEN SETUP pages Select the icon for SCREEN SETUP 1 14 so the Screen Setup 1 screen appears Select how you would like to have the screen configured to show a combination of baler and 77E system information by selecting the boxes When you select one of the boxes a pop up screen will appear that shows the selections available 14 13 12 11 ...

Page 18: ...djust the Moisture Alarm Settings in the Field Setting Screen Note that the low moisture alarm must be set lower than the high moisture alarm The moisture alarms can be turned off by setting the low setting 9 and the high setting 70 When the alarms are turned off they will say OFF next to the values Select the MAIN SCREEN 1 icon 18 from the Menu Bar Verify that your MAIN SCREEN 1 and MAIN SCREEN 2...

Page 19: ...d by arrows 19 25 are as follows 19 Next Implement Button 20 Moisture Content 21 Last Bale Average Moisture Content 22 IPM Status Icon The status icon 22 indicates the system is connected to the baler An X over the status icon indicates the system is A Not in an application mode B Paused through a Manual Pause b Baler End of Row EOR Pause PTO speed 600 rpm 20 21 22 19 ...

Page 20: ... the Pro 1200 Series Monitor 1 Select the baler Setup tab in the top right corner of the baler run screen 2 Open the Diagnostics tab by pressing the stethoscope icon and select the System Information tab 3 On the System Information page press and hold the first blank square box under the down arrow on the right side of the screen for 10 Seconds ...

Page 21: ... the Code 1379 when the numbers appear The screen below will appear alerting you Dealer Mode Activated Press OK and go back to the balers home screen 5 Select the baler Setup tab in the top right corner of the baler run screen Then press Machine Configuration from the baler setup page wrench icon at top ...

Page 22: ... down The moisture sensor selection will now read DCP on the Machine Configuration page The current bale moisture content will now display above the baler next to the water droplet and the previous bale moisture will display next to the bale in above the are above the bale chute below Previous Bale Moisture Current Bale Moisture ...

Page 23: ...77E system through the John Deere ISOBUS monitors 2600 Series Monitors 1 Starting from the Home Page select the Up Arrow with the dot on top 2 On the Machine Setup page that will appear select soft key D Page Right 3 On the next page select the Harvest Tec option The Check mark indicates that the system is now on ...

Page 24: ...ftware version 8 10 2393 23 or later is required on the display to ensure compatibility Earlier versions are not all compatible This information can be found by selecting Menu in the lower right hand corner of the display select the third tab down labeled System press Software Manager then the Version Information tab and the software versions will be displayed Figure 1 Current moisture Last bale m...

Page 25: ...Harvest Tec 77E is powered up correctly and active on the ISOBUS the icon labeled Forage Harvest Tec Inc will display If the files are still loading you will see a loading status Figure 4 Once the files are loaded onto the display you will receive a warning Figure 5 to inform the operator that another device has been added onto the ISOBUS This can be accepted and then selecting the Harvest Tec dev...

Page 26: ... Tec system is connected you can also access the 77E by following these screens Moisture System Setup Tablet with PRECISION BALE APP MWM Chute Note Screen layouts may differ slightly if setup is performed thru Baler Virtual Terminal Press SETUP Press the SENSOR cell ...

Page 27: ...tup AGCO 2200 3000 CNH 2200 3000 John Deere 2200 3000 Krone 2200 3000 Other 2200 3000 If the reading is within range no adjustments need to be made This range is for both 3 and 4 1M 1 2M wide balers Moisture System Setup CHUTE DENSITY MOISTURE OFFSETTING Note Chute Density setting may be changed after calibration is complete to compensate for various crop types and allow for minor moisture reading...

Page 28: ...med A zero adjust should be performed on initial installation It is also recommended completing a zero adjust calibration at the beginning of each season 7 When reading moisture with 77E microwave sensors why can I not select Automatic mode MWM Bale Chute sensors can only be used in Manual Mode due to limited features of this moisture sensor The 77E sensors use the same operating software found in...

Page 29: ...nd application rate displays zero 1 Model 77E moisture only kit does not provide a baling rate or actual rate of preservative MWM moisture reads low all the time 1 Bale Rate sensor out of adjustment 2 MWM Chute is not properly selected in setup menu 1 Verify Bale Rate sensor is not damaged and is sensing the metering wheel moving each time 2 Reference Moisture System setup section ICM light will n...

Page 30: ... 006 7640MWL Metering Wheel Sensor Plug on Baler Harness Deutsch Plug Number DT06 3S 006 7640MWL RX Microwave Moisture Harness Deutsch Plug Number DT06 08SA CE10 Pin 1 Black White Ground Pin 2 Red White 12V Power Pin 3 Orange CAN High Pin 4 Blue CAN Low Pin 5 Plugged Pin 6 Plugged Pin 7 Brown Signal Pin 8 Black Ground 006 7640MWL TX Microwave Moisture Harness Deutsch Plug Number DT06 08SA CE10 Pin...

Page 31: ... White Ground CAN X Pin 3 Orange CAN X High Pin 4 Blue CAN X Low Pin 5 Yellow ISO CAN High Pin 6 Green ISO CAN Low Pin 7 Red 12V from ECU Pin 8 Black Ground from ECU 006 765CPH Key Switch Wire Deutsch Plug Number DT06 4S Pin 1 Red 12V Key Pin 2 Pin 3 Pin 4 Black Ground from ECU Pin 1 Red 12V from ECU Pin 2 Plugged Pin 3 Red White 12V CAN X Pin 4 Black White Ground CAN X Pin 5 Orange CAN X Hi Pin 6...

Page 32: ... 12V Switched Pin 2 Yellow CAN High Pin 3 Green CAN Low Pin 4 Black Ground from ECU 006 7670A Diagnostic Integration Tractor Side Deutsch Plug Number HD16 9 19395 Pin A Black Ground from ECU Pin B Pin C Pin D Pin E Red ECU 12V Switched Pin F Pin G Pin H Green CAN Low Pin J Yellow CAN High 1 3 v 2 v 4 v ...

Page 33: ...06 7640MWL 1 5 Microwave RX Sensor 006 4641MRX 1 6 End of Bale Bracket Meter Wheel Bracket 001 4648SS 1 7 Proximity Sensor Meter Wheel Sensor 006 7401 1 8 77E MWM TRACTOR HARNESS 006 764IC 1 9 ICM ISO COMMUNICATION MODULE 006 6673 1 10 700 SERIES ISOBUS INTEGRATION IN CAB DIAGNOSTIC PORT 006 7670A 1 NP Power Comm Extension Harness 25 006 7640FMX 1 Complete Assembly 77E Ref 1 10 5 6 3 4 2 7 1 8 9 1...

Page 34: ...ned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harvest Tec Inc liable for injury or damages of any kind direct consequential or contingent to persons or property Furthermore this warranty does not extend to loss of crop losses caused by delays or any expense prospective profits or for any other reason Harvest Tec Inc s...