10
Installation of Star Wheel Moisture Sensors
– 600BBHD
1. Locate the two star wheel moisture sensors (030-4641U) and star wheel reinforcement
brackets (001-4644BBHD) show on the right and parts bag A.
2. The two pre-drilled mounting holes for the star wheels are located past the knotters on the
side of the top support bar running the length of the bale chute (Figure 1).
3.
Position the star wheel mounting holes and mark the width of the star wheel 3” (88mm). As
well as the depth
of the star wheel of 2” (50mm). This piece will need to be removed from
the baler bracket in order for star wheel to fit flush with baler bracket (Figure 2).
4. Position the left side reinforcement bracket (001-4644BHD) around the star wheel. This will be labeled
‘Left
Side of Baler, This Side Up’.
Shown mounted in Figure 3. Repeat mounting the star wheel and installation
of the reinforcement bracket on the right side of baler.
5. Locate the end of baler sensor bracket (001-4644SS) and the two bale rate sensors
(006-7303S). The sensors will be pre-mounted to the bracket. Mount the bracket
and sensors as shown in Figure 4. Sensors only mount on the left side of baler.
Figure 3
Figure 4
001-4644BBHD
Figure 2
Figure 1
001-4644SS