![Harvest TEC 200DM Owner'S Manual Download Page 8](http://html1.mh-extra.com/html/harvest-tec/200dm/200dm_owners-manual_2103702008.webp)
8
Control Box Installation
Locate a safe location in the cab of the tractor to place the
control box (006-2473SB). Recommended location is as close
to the tablet or phone being used to control the system.
Connect the Power Harness (006-2470P) and the Baler
Power Communication Harness (006-2470LS).
The control box (006-2473SB) is equipped with a green light
to indicated both power and connection.
Plug the tablet/phone cord into the
communication port (closest to light)
and indicated by:
Slow Blink
–
System has power but not connected to phone or tablet.
Solid Green
– Device is connected.
**
It is recommended for proper communication that the original phone/tablet power cable is used. Many lower
cost power cables do not meet requirements to properly charge and communicate to the Harvest Tec H2O
module.
End of Bale Sensor Installation
– 200FCA (Optional)
The end of bale sensor is used to determine when the baler needle arm moves. With this information the
system is able to show the average moisture of the previous bale. Part number for kit is 200FCA.
Mount the 006-7400 sensor to the mounting bracket 001-4648RB as shown below. Mount the assembly on the
right side of the baler chamber. The face of the sensor needs to be parallel to the arm attached to the needles.
*Note: The bracket may need to be slightly bent for the proper positioning.
Mark and drill two 3/8” (10mm) holes. Install the sensor using two 5/16” x 1“ allen head bolts, locks, and nuts.
The end of the sensor needs to be no greater
than 1/4” (7mm) away from the needle arm. Tighten nuts on
sensor after adjustment.
The harness will need to be routed toward the harness at the tongue of the baler.
Secure with cable ties and
take care to avoid pinch points. The harness extension (006-7400EXT) may need to be used.
006-4648RB
006-7400
006-2473SB