background image

4

Safety Stand

5502-002 Rev 2.0 • www.btxonline.com

The BTX Safety Stand is a safety device for use with BTX disposable cuvettes and flatpack chambers. Its unique design ensures that no 
current can be delivered unless the lid is closed, therefore protecting the user from high voltages. Up to two cuvettes can be electroporated 
at once, thus decreasing experimentation times. Please refer to the Product Compatibility table below for compatible BTX electroporators 
and accessories.

Introduction

Product Compatibility
BTX Safety Stand Item # 45-0207

47-0208

47-0203

47-0209

47-0610N

Compatible  
BTX Generators

ECM 399

ECM 630

ECM 830

ECM 2001*

Gemini X2

* When used with 

F/F adapters,  
Item 45-0088, 
Sold separately

ECM 399

ECM 630

ECM 830

ECM 2001**

Gemini X2

** When used  

with included  
F/F adapters,  
Item 45-0088

AgilePulse MAX

ECM 2001+

AgilePulse MAX

ECM 2001+

AgilePulse PLUS

Compatible  
BTX Cuvettes

All 1 mm, 2 mm,  
and 4 mm gap 
BTX cuvettes

All 1 mm, 2 mm,  
and 4 mm gap  
BTX cuvettes

All 1 mm, 2 mm,  
and 4 mm gap  
BTX cuvettes

All 1 mm, 2 mm,  
and 4 mm gap  
BTX cuvettes

All 1 mm, 2 mm,  
and 4 mm gap  
BTX cuvettes

Compatible  
BTX Flatpacks

45-0109

45-0110

45-0109

45-0110

47-0206

45-0109

45-0110

45-0109

45-0110

47-0206

45-0109

45-0110

47-0206

Note: For compatibility with older models, please contact BTX Technical Support. 

Summary of Contents for BTX 45-0207

Page 1: ...45 0207 Model 630B Cuvette Safety Stand 47 0208 Extended Capacity Flatpack Safety Stand 47 0203 AgilePulse MAX Cuvette Safety Stand 47 0209 AgilePulse MAX Extended Capacity Flatpack Safety Stand 47 0610N AgilePulse PLUS Extended Capacity Flatpack Safety Stand ...

Page 2: ...any reference to electroporation and electrofusion We extract the pertinent experimental conditions and yields from these papers to help us in our efforts to help you In addition to tracking publications we are available to you for support at any time for advice in experimental design product recommendations troubleshooting and any other relevant technical advice We thank you again for your invest...

Page 3: ...y Stand 5502 002 Rev 2 0 www btxonline com Table of Contents SUBJECT PAGE Warranty Information 2 General Safety Information 3 Introduction 4 Operation Getting Started 5 Specifications 6 Ordering Information 7 ...

Page 4: ...ises within the warranty period promptly contact BTX 84 October Hill Road Holliston Massachusetts USA 01746 1388 using our toll free number 1 800 272 2775 US Only or 508 893 8999 E mail support hbiosci com Goods will not be accepted for return unless an RMA Returned Materials Authorization number has been issued by our customer service department The customer is responsible for shipping charges Pl...

Page 5: ...roduct Read all labels on product to ensure proper usage High Voltage Risk These BTX Safety Stands are designed to connect to a high voltage power supply adjustable to 3 000 V High voltage power supplies present a serious risk of personal injury if not used in accordance with design and or use specifications if used in applications on products for which they are not intended or designed or if they...

Page 6: ...0208 47 0203 47 0209 47 0610N Compatible BTX Generators ECM 399 ECM 630 ECM 830 ECM 2001 Gemini X2 When used with F F adapters Item 45 0088 Sold separately ECM 399 ECM 630 ECM 830 ECM 2001 Gemini X2 When used with included F F adapters Item 45 0088 AgilePulse MAX ECM 2001 AgilePulse MAX ECM 2001 AgilePulse PLUS Compatible BTX Cuvettes All 1 mm 2 mm and 4 mm gap BTX cuvettes All 1 mm 2 mm and 4 mm ...

Page 7: ...t the distance between the contacts using the black roller Note the adjustment will remain the same after the first time do not readjust the roller with every cuvette However check contact periodically to ensure good current flow Close the safety stand shield 4 Switch on the BTX electroporator Check that all instrument settings and connections are correct Deliver electroporation pulse protocol by ...

Page 8: ...ge Temperature 10 to 70 C Operating Temperature 5 to 40 C Intended Use Indoor Use Only Relative Humidity 20 to 80 Maximum Altitude 2 000 m 6 562 ft Pollution Degree II Insulation Category CAT I Physical Characteristics Overall Dimensions 45 0207 47 0203 L x W x D 12 7 x 10 2 x 17 8 cm 5 x 4 x 7 in Overall Dimensions 47 0208 47 0209 L x W x D 12 7 x 10 2 x 19 0 cm 5 x 4 x 7 5 in Weight 1 kg 2 3 lb ...

Page 9: ...sfer pipettes Pkg of 10 45 0125 BTX Cuvettes Plus 2 mm gap 400 µl Sterile Blue cap individually wrapped with transfer pipettes Pkg of 50 45 0141 BTX Cuvettes Plus 2 mm gap 90 µl Sterile Blue cap bulk wrapped in packages of 100 cuvettes per pkg Pkg of100x24 45 0135 BTX Cuvettes Plus 4 mm gap 800 µl Sterile Yellow cap individually wrapped with transfer pipettes Pkg of 10 45 0125 BTX Cuvettes Plus 4 ...

Page 10: ...US Canadian Customers phone 508 893 8999 fax 508 429 5732 e mail support hbiosci com website www btxonline com International Customers To locate a distributor near you please visit our website at www btxonline com ...