12/20/11
888-2595-001
5-15
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
ZX Series
Table 5-2 PA TEMP test point scale
Max PA
temperature
(degrees C)
PA TEMP test
point (volts)
0
0.14
10
0.17
20
0.20
25
0.23
30
0.26
35
0.30
40
0.35
45
0.40
50
0.47
55
0.54
60
0.63
65
0.74
70
0.86
75
1.00
80
1.16
85
1.34
90
1.55
95
1.79
100
2.06
formula: T(
o
C) = 35.294Ln(V) + 75.388