RF-5800H 125-WATT COMMUNICATION SYSTEM
TROUBLESHOOTING
6-2
6.2 TROUBLESHOOTING PROCEDURES
6.2.1
General
Troubleshooting begins with performing the maintenance turn-on procedure. The maintenance turn-on procedure
references the non-BIT and BIT troubleshooting procedures.
6.2.2
Maintenance Turn-On Procedure
The maintenance turn-on procedure is used to guide the maintainer through the proper RF-5800H-MP front panel
settings to power up the RF-5800H 125-Watt Communication System from a de-energized state to a fully
operational state. In each step the maintainer is to observe the RF-5800H 125-Watt Communication System for
normal operating conditions. Faults may be determined by using BIT or visual observation. BIT faults for all units
are displayed on the RF-5800H-MP KDU.
Perform the following procedure to power up the RF-5800H-MP and execute BIT:
a.
Turn the power switch of the RF-5051PS to the ON position. If the system is vehicular, skip this step and
proceed directly to Step b.
b.
Rotate the FUNCTION switch to the PT position. If the RF-5800H-MP does not power-up, verify that the
power source is on. If necessary proceed to Paragraph 6.2.3, non-BIT fault troubleshooting.
c.
Press the OPT button.
d.
If necessary, press the left/right arrow buttons to select the TEST field.
NOTE
While in TEST mode, the radio cannot receive or transmit.
e.
Press the ENT button.
f.
If necessary, press the left/right arrow buttons to select the ALL field.
g.
Press the ENT button.
If the RF-5800H-MP displays a fault code on the LCD after completing the BIT test, record the fault
code and proceed to Paragraph 6.2.4, BIT Troubleshooting.
If the RF-5800H-MP displays no error messages, try to operate the RF-5800H 125-Watt Communication
System in an attempt to generate a run-time fault. If a run-time fault is generated, refer to the non-BIT
troubleshooting procedures in Paragraph 6.2.3.
If a run-time fault cannot be generated and the RF-5800H 125-Watt Communication System is still not
operating properly, refer to the non-BIT troubleshooting procedures in Paragraph 6.2.3.
Summary of Contents for RF-5800H
Page 3: ......
Page 35: ...RF 5800H 125 WATT COMMUNICATION SYSTEM INSTALLATION 2 6 This page intentionally left blank ...
Page 41: ...RF 5800H 125 WATT COMMUNICATION SYSTEM INSTALLATION 2 14 This page intentionally left blank ...
Page 47: ...RF 5800H 125 WATT COMMUNICATION SYSTEM OPERATION 3 2 This page intentionally left blank ...
Page 81: ...RF 5800H 125 WATT COMMUNICATION SYSTEM PARTS LIST 7 16 This page intentionally left blank ...
Page 89: ...RF 5800H 125 WATT COMMUNICATION SYSTEM APPENDIX A A 4 This page intentionally left blank ...