13
Operating Instructions for the
Thermoelectric Generator (TEG)
In the event of a failure of the TEG, the LED light and/or fan will not run. The TEG
should be replaced by following the below instructions before the fire is used again.
1. Remove side panels by pulling
the top out of the clips
2. Remove rear panel by pulling
out the of the clips
3. Remove back section of the duct
by undoing screws
5. Remove the top and bottom fire
bricks followed by the rear air
tube. The rear airtube is held in by
2 pins, remove and slide out.
Once removed, this exposes 3 hex
nuts. Undo these and the TEG will
be released
6. The TEG is now released, re-
place entire unit including the con-
trol box. Reverse these steps.
4. Unscrew control box from the
side once side panel has been re-
moved.