c. Check that the 20 pin spring connector at the bottom of the
back module does not have any bent or pressed in pins. (See
Figure B-2
.) Even a slightly depressed or bent pin may cause
genlock issues.
Figure B-2.
Back Module to Front Module Connector
d. If there are bent pins carefully re-position them to their correct
positions.
If this is not possible then the back module can be exchanged
for a new one. Use part number ENC/ENS6800
+
DR.
6. If the ENC/ENS6800
+
can still not be genlocked, attempt doing a
Factory Recall
on the module.