14
ENC/ENS6800
+
Installation and Operation Manual
Chapter 2: Installation
the FR6802
+
frame genlock input. This is determined by the
position of jumper
J1
on the ENC6800
+
or ENS6800
+
module as
shown in
Figure 2-3
.
•
Genlock 2
(labeled
625
on the rear module): If this setting is
chosen, the genlock source will be taken from the
Genlock 2
input
of the rear module and is independent of the jumper
J1
setting.
•
Auto
: Varies between
Genlock 1/Frame
and
Genlock 2
genlock.
This is used if the card is expected to auto-switch between an NTSC
or PAL-M reference and a PAL-B reference based on the video
input. In this case one reference input would be applied to the
Genlock 2
input, and the other reference input would be applied to
either
Genlock 1
or
Frame
. Then when the input signal changes
between SD 525 and SD 625, the genlock will automatically switch
to the appropriate genlock source. Remember that jumper
J1
determines whether
Genlock 1
or
Frame
is the source of the first
genlock input (see
Figure 2-3
).
When the genlock source input is valid, the Genlock LED will turn
green. If you are using an ENS6800
+
and the Genlock LED never turns
green, ensure that the
Frame Sync Mode
parameter is not set to Delay.
Setting Jumper P1 for Reclocking and IO_DELAY Output
Follow this procedure to set the
P1
jumper to select Reclocked SDI or
IO_DELAY output to a BNC output connector on the back module:
1. Locate jumper
P1
on the module. See
Figure 2-1 on page 12
.
2. Place a jumper on pins 2 and 3 to set the module for
SDI RCLK
, or
place a jumper on pins 1 and 2 and another jumper on pins 3 and 4
to set the module to output
IO_DELAY
.
Figure 2-4.
Jumper P1 Settings for Reclocked SDI or
IO_Delay Output
Note
Even though the rear module is
labeled
525
for Genlock 1 and
625
for Genlock 2 either type of
standard can be applied to either
of the inputs. They are not 525
or 625 dependent. However the
same type of genlock format
(NTSC or PAL-B) should never
be applied to both genlock input
sources at the same time.
Note
The ENC6800
+
does not
have IO_DELAY.
1
2
3
4
1
2
3
4
Reclocked SDI output
IO_Delay output
Summary of Contents for ENC6800+
Page 2: ......
Page 8: ...vi ENC ENS6800 Installation and Operation Manual Contents...
Page 48: ...34 ENC ENS6800 Installation and Operation Manual Chapter 3 Operation...
Page 54: ...40 ENC ENS6800 Installation and Operation Manual Chapter 4 Specifications...
Page 60: ...46 ENC ENS6800 Installation and Operation Manual Appendix A Filters...
Page 66: ...52 ENC ENS6800 Installation and Operation Manual Appendix B ENC ENS6800 Troubleshooting...
Page 79: ......