Harris Corporation
Constellation™
Installation and Commissioning
4-3
INSTALLATION AND
CO
MM
ISSIO
N
IN
G
Ensure that the test equipment has
•
the current calibration
•
the proper connector(s)
so that you will get a correct reading from the test
equipment.
Table 4-2: Recommended test equipment
Test
Equipment
Specification
Model
Function
Digital
multimeter
3-1/2 digits
Accuracy: 0.3% to
±
60
VDC, 2% from 10
mVAC
Fluke Model 77 or
equivalent
To test the
battery voltage.
To align the
antenna.
Frequency
counter
Universal frequency
counter with 10-digit
accuracy and 2160-
MHz ability
Agilent 53131A
or equivalent
To adjust the
frequency of the
Transmitter and
Receiver.
Power meter
100 kHz to 26.5 GHz
±
1% accuracy
Agilent E4418B
or equivalent
RF transmitter
power output
Power sensor
−
25 dBm to +33 dBm
(medium and high
power heads)
Agilent 8485A
(-30 to +20
dBm) Agilent
8481H
(-10 to +35
dBm) Agilent
8485D
(-20 to -70 dBm)
or equivalent
Summary of Contents for Constellation
Page 1: ...Point to Point Digital Radio Constellation Installation Maintenance next level solutions ...
Page 2: ......
Page 3: ...Constellation Microwave Radio INSTALLATION AND MAINTENANCE MANUAL June 20 2002 IMN 112871 E07 ...
Page 16: ...Constellation 2002 June 20 TOC 12 ...
Page 20: ...Constellation 2002 June 20 2 ...
Page 76: ...Constellation 2002 June 20 4 34 ...
Page 136: ...Constellation 2002 June 20 10 12 ...
Page 150: ...Constellation 2002 June 20 11 14 ...
Page 186: ...Constellation 2002 June 20 12 36 ...
Page 210: ...Constellation 2002 June 20 A 16 ...
Page 236: ...Constellation 2002 June 10 F 2 ...
Page 240: ......
Page 242: ......
Page 248: ...Constellation 2002 June 20 G 6 ...
Page 262: ...Constellation 2002 June 20 I 14 ...
Page 263: ......