FAX 5/10/20/30/40KW
October 28, 2013
3
‐
23
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
Note
Under normal conditions the airflow % typically will be between 75 and 90 %.
3.9.8
SETUP>TX CALIBRATE>PWR BLOCK CAL
This
procedure
is
not
in
the
FAX5/10
menu
since
there
is
only
one
power
block
and
it
is
calibrated
using
the
TX
PWR
CAL
menu.
In
a
FAX20/30/40
there
will
be
multiple
power
blocks
and
voltages
for
each
will
appear
in
the
menu.
See
Section
5
of
this
manual
for
detailed
power
block
calibration
procedure.
The
power
block
power
cannot
be
measured
directly
with
an
in
‐
line
meter,
so
the
power
will
be
estimated
based
on
transmitter
power
which
should
be
calibrated
prior
to
calibrating
the
power
block.
The
power
block
should
be
calibrated
at
the
2
%
above
power
block
power.
The
following
example
is
for
FAX20@
20
kW:
(TX
TPO/#
of
power
blocks)
+
2%
(20000/2)
=
10000
10000
+(10000*
2%)
=
10,200
Watts
The
2%
is
an
estimate
of
loss
in
the
splitting
and
combining
systems
within
the
FAX.
Table 3-12 SETUP>TX CALIBRATE>AIRFLOW SET
Menu
SubMenu
Description
PB1
AIRFLOW
AIRFLOW
Airflow
Voltage
to
ADC
(Display
Only)
AIRFLOW
CAL
%
of
airflow
currently
being
measured
by
transmitter
SET
PB1
100%
YES
or
NO;To
set
airflow
the
transmitter
fans
should
be
running
full
speed
which
is
100%
airflow.
Table 3-13 SETUP>TX CALIBRATE>PWR BLOCK CAL
Menu
Description
UNIT
PWR
10200W;
Power
that
the
power
block
will
be
calibrated
to.
CALIBRATE
YES
or
NO
PB1
FWD
3.50
V;
Calibration
reference
voltage
for
power
block
forward
power
PB1
RFLD
1.73V;
Calibration
reference
voltage
for
power
block
reflected
power
PB2
FWD
3.50
V;
Calibration
reference
voltage
for
power
block
forward
power
PB2
RFLD
1.73V;
Calibration
reference
voltage
for
power
block
reflected
power