Section-5 Maintenance
October 28, 2013
5
‐
10
Copyright
©2013,
Harris
Broadcast
WARNING:
Disconnect
primary
power
prior
to
servicing.
888
‐
2720
‐
001
STEP 12
Inspect
all
exposed
PC
boards
for
signs
of
heat
discoloration
or
rings
of
dried
solder
flux,
an
indication
of
partial
solder
melting.
STEP 13
Shine
light
through
combiner
cover
(but
do
not
remove)
to
inspect
output
assembly
combiner
coils
for
any
corrosion
that
is
crusty
or
pasty.
It
is
normal
for
the
coils
to
change
color
over
time.
This
does
not
negatively
impact
their
performance,
provided
it
is
simple
oxidation
and
not
a
more
aggressive
corrosion
due
to
harsh
air
pollution
components.
STEP 14
Verify
all
push
‐
on
(faston)
connections
are
fully
seated
on
PA
backplanes,
PS
interface
board,
AC
mains
inputs,
etc.
STEP 15
Shine
light
through
combiner
support
frame
to
deck
of
output
assembly
and
inspect
ballast
loads
for
burning
or
cracking.
STEP 16
Close
amplifier
chassis
rear
door.
STEP 17
Return
hex
key
to
storage
position.
STEP 18
If
transmitter
is
FAX20kW,
visually
inspect
the
6kW
RF
reject
load
on
rack
cabinet
upper
rear
for
signs
of
cracked
resistors
or
other
debris.
STEP 19
Remove
AC
mains
lockout
precautions
and
apply
AC
mains
power.
STEP 20
Press
front
panel
ON
button
to
turn
transmitter
on.
STEP 21
Verify
transmitter
returns
to
full
power
and
no
alarms
are
reported.
STEP 22
As
desired,
use
off
‐
air
opportunity
to
verify
integrity
of
all
safety
interlock
circuits
such
as
station
load
temp
sensor,
patch
panel
position
switches,
coaxial
switch
position
switches,
etc.
STEP 23
As
desired,
use
off
‐
air
opportunity
to
operate
transmitter
into
station
test
load
and
verify
test
load
integrity.
STEP 24
As
desired,
use
off
‐
air
opportunity
to
verify
reserve
exciter
and
exciter
switchover
functionality
(where
applicable).
STEP 25
As
desired,
use
off
‐
air
opportunity
to
verify
reserve
IPA
and
IPA
switchover
functionality.
STEP 26
Note
any
findings
and
resolutions
in
station
maintenance
log.
5.4
Date and Time Battery
The
date/time
battery
(20mm,
3V,
lithium
coin
battery
CR2032)
is
normally
installed
at
the
factory.
Check
and
verify
battery
is
installed.
The
battery
mounts
on
the
front
panel
Display/Control
board.
Perform
the
following
steps
to
install
or
replace
the
battery.
STEP 1
Open
front
panel
by
turning
the
upper
and
lower
thumb
screws
counterclockwise.
STEP 2
Swing
the
panel
door
open
to
access
the
Display/Control
board
located
along
the
top
inside
of
the
door.
Note,
the
battery
holder
is
located
on
the
upper
left
hand
corner
of
the
board.
STEP 3
Remove
battery
from
package
(Pt.
No.
660
‐
0054
‐
000)
and
slide
battery
into
holder,
with
positive
side
up
against
clip,
until
it
is
fully
seated.