11
When the voltage drops or a flow interruption occurs, the timer will be reset and its time
will be completely expired again.
This procedure runs if the set time. After the time has elapsed, the pH dosage and
measurement will continue, but no more chlorine will be generated. At the next 24 hours
the timer resumes its settings or set time.
When confirming and after setting the option Salt time a screen appears with the message:
After each power or flow interruption, the electrolysis will operate for xx
hours and xx minutes (your set time values). With continuous electrical
current, the electrolysis will operate for xx hours and xx minutes per 24
hours.
After each power or flow interruption, the electrolysis will operate for xx hours and xx
minutes (your set time values). With continuous electrical current, the electrolysis will
operate for xx hours and xx minutes per 24 hours.
Press OK to return.
Option 2: Salt Rx
after the selection comes a notification screen
- The sequence is:
Measurement values swimming pool water 40 sec
Chlorine generation by electrolysis 4 min
pH dosage 1 min (if setpoint is not reached)
Back measurement values swimming pool water
When the setpoint Rx is reached the sequence will continue to run but no more chlorine
will be generated, chlorine will be generated again when the measured Rx value has
dropped below the setpoint Rx.
Summary of Contents for Hydrolyse EC12