background image

 

 
 
 
 
 

 

 

 

 
 
 

 

 

 

Summary of Contents for Hydrolyse EC12

Page 1: ......

Page 2: ...Rx set up the Rx set point 14 Table 1 14 Specification of Ph addition 16 Calibration and verification Chlorine Ph 16 Connecting a flow switch 16 Connecting a level switch 17 Overview chlorinator 17 I...

Page 3: ...riginal standard parts Failure to do so will void your warranty Characteristics Durable the materials used are chlorine acid sulfuric and base resistant They can withstand prolonged exposure to swimmi...

Page 4: ...r treatment equipment without a plug for the devices Dit device is elektrisch connected to the salt electrolysis device Attention The electrical installation shall be carried out in such a way that Th...

Page 5: ...be installed inside If you want to do this outdoors you need to contact your supplier The dosing device mag shall not be used with hydrochloric acid HCl The electronics dosing devices of the applianc...

Page 6: ...nut with pliers or wrench to tighten the cap Failure to do so may result in a leak and is not covered under warranty 3 Create a separate grounding for your Salt Electrolysis with grounding pen 4 Conn...

Page 7: ...ps product code ZFPX4640 into the electrode bases to prevent water from spraying out of the electrode bases during calibration 2 The electrode calibration procedure may take several minutes To ensure...

Page 8: ...can either only calibrate Ph ef only Rx or both at the same time A timer will stop after 120 seconds and give a notification as to whether the calibration has succeeded Reasons for a failed calibratio...

Page 9: ...is between 20 40 ppm 20 40 g 10 m 11 Set parameters Several parameters need to be set Press the middle key You will see the following screen 11 1 Language You can set a different language Press the m...

Page 10: ...s dosing method pH and liquid chlorine are never dosed at the same time Explanation of the continuous dosing method The pumps always run when the pH and or redox setpoint is not reached If you choose...

Page 11: ...rent the electrolysis will operate for xx hours and xx minutes per 24 hours After each power or flow interruption the electrolysis will operate for xx hours and xx minutes your set time values With co...

Page 12: ...added as a stabilizer PH must always be set when using salt electrolysis When chlorine is produced by the salt electrolysis unit PH NaOH is formed as a by product It is not possible to add both PH and...

Page 13: ...k into effect With an uninterrupted dosage for 240 min or 4 hours the device goes into alarm mode and stops the functionality of the dosing pumps and electrolysis Alarm off Never use the device in the...

Page 14: ...n ppm Below is a table which shows the ratios between mV and pH and the corresponding ppm For example your device has the following values on the screen pH 7 2 and redox of 740 then your pool water ha...

Page 15: ...mV 698 694 684 680 675 670 666 661 657 652 647 643 638 0 95 mV 706 702 692 687 682 677 673 668 663 658 654 649 644 0 9 mV 713 708 698 694 689 684 679 674 669 664 659 654 650 0 95 mV 720 715 705 700 6...

Page 16: ...ine must be regularly weekly verified by means of a proper measurement with color for example Poollab ZWMX1060 Every installation should be calibrated at least once a year In case of a long swimming s...

Page 17: ...limescale removal and fault alarm You can adjust the chlorine concentration according to your needs to achieve the goal of efficiency and environmental friendliness Product differentiating facts Contr...

Page 18: ...e system setting before a system failure including the acceleration status the acceleration status timer is reset Model Chlorine production Ideal business location EC8 8g h unit suitable for swimming...

Page 19: ...am 1 or diagram 2 5 Before installing the salt chlorinator make sure that the water flow corresponds to the direction indicated by the chlorinator 6 When connecting the pipes use only line suitable fo...

Page 20: ...pressing the or button users can adjust the chlorine concentration level as needed users can use level 1 5 1 level is the smallest and 5 level is the highest The higher the level the higher the conce...

Page 21: ...mal operation shows the corresponding error code when a problem occurs 2 level indicator light 1 light stands for level 1 2 light stands for level 2 5 lights represent 5 level 3 Button for level contr...

Page 22: ...ter The normal temperature range is between 10 45 degrees Celsius First check if error code E7 is present if this is the case check if the temperature sensor is confirmed if this is the case replace t...

Page 23: ...if the corresponding temperature sensor is attached replace the sensor if this is the case E7 water temperature sensor defective the error must be corrected manually first check if the corresponding t...

Page 24: ...contain a certain amount of salt the concentration of salt in the water strongly depends on the water source Users can use a portable NaCl tester or a salinity pen to test the skin and salt concentra...

Page 25: ...salt concentration The only way to reduce the salt concentration is to drain some of the pool water and replace it with fresh water 1 6 To reduce the loss of chlorine caused by UV radiation on the out...

Page 26: ...serious injury Never mix acid and liquid chlorine Keep the equipment and chemicals out of the reach of children Always wear safety gloves and goggles when working on the system Switch off the power T...

Page 27: ...proportional dosing No action required Acid pump does not pump There is a flow siwtch connected and this indicates that there is no flow Verify flow and flow switch go to setting flow switch no There...

Page 28: ...device to pH Electrode broken Replace electrode pH always 7 also in calibration liquids pH 4 and pH 9 pH probe broken Replace pH probe and re calibrate Device comes in alarm Rx too low Rx 150 Impurit...

Page 29: ...udetector A flow siwtch is connected and it indicates that there is no flow Verify flow and flow switch go to setting flow switch no Chlorine pump continues to dosing Setpoint not yet reached Check se...

Page 30: ...nd have the dosing device reduce the pH Acid container is empty Replace acid container Electrode broken Replace electrode Device goes into alarm pH too low pH 5 5 Verify pH by color method Correct pH...

Page 31: ...et the gas escape Check the pipes for accumulated gas Check the pump Cell sensor cable is defective or wrongly connected white wire Check the sensor cable white cable Cell sensor is dirty Clean up see...

Reviews: