Conformance to overseas standards
7
The values displayed on the name plate for each model are shown below.
Model
Item
MMAB09
(1) Output at point A
W
251
(2) Voltage at point A
V
136
(3) Allowable continuous current
A
2.5
(4) Speed at point A
r/min
3000
(5) Frequency at point A
Hz
250
(6) Allowable ambient temperature
℃
40
(7) Number of phases
-
3
Model
Item
MMAB12
(1) Output at point A
W
406
(2) Voltage at point A
V
129
(3) Allowable continuous current
A
4.2
(4) Speed at point A
r/min
2500
(5) Frequency at point A
Hz
208
(6) Allowable ambient temperature
℃
40
(7) Number of phases
-
3
Model
Item
MMAB15
(1) Output at point A
W
754
(2) Voltage at point A
V
125
(3) Allowable continuous current
A
7.8
(4) Speed at point A
r/min
2000
(5) Frequency at point A
Hz
167
(6) Allowable ambient temperature
℃
40
(7) Number of phases
-
3
Model
Item
MMAA21A
(1) Output at point A
W
1320
(2) Voltage at point A
V
100
(3) Allowable continuous current
A
20.0
(4) Speed at point A
r/min
1000
(5) Frequency at point A
Hz
133
(6) Allowable ambient temperature
℃
40
(7) Number of phases
-
3
Summary of Contents for MMA Series
Page 10: ...Conformance to overseas standards 8...
Page 32: ...1 13 Cable specifications 1 21 Outlines 1 Appe...
Page 48: ...3 3 Location and installation 3 7 Installing the motor 3 Appe...
Page 49: ...Chapter 4 Options This chapter provides information on the options 4 1 Options 4 1...
Page 53: ...Chapter 5 Appendix A 1 Unit conversion 5 1 A 2 Calculating inertia moment 5 3...
Page 60: ......