1-5 Accuracy
Items
Stroke
Accuracy
Pay Load
Repetitive accuracy
1 mm
±0.1
m or less
9.8
~
49N
(1
~
5kgf)
Full stroke
positioning accuracy
Full stroke
10
m or less
for 10mm travel
Short stroke
positioning accuracy
Stroke:40
m
0.4
m pitch
2
m or less
for 40
m travel
Lost motion
1 mm
5
m or less
Note: Measuring temperature: 20ºC±1ºC
1-6 Testing system and standards for testing
1-6-1 Testing system
The LA series linear actuators are guaranteed with the following tests under JIS B6201 standard using our
original measuring system.
Main instruments:
Laser Linear encoder: CANON L-104
Resolution:
0.01
m
Repeatability:
0.01
m or less
Interface and Indicator:
CANON CL-40
Control unit:
Harmonic drive
HA-360-1A
Controller MYCOM Co.
SCN-110
Personal Computer
Control Unit: