NOTICES TO USE A DRIVER UNIT
Notices for designing and application: Always read the relating technical documents for the purpose.
Always use the driver unit in the specified
environment.
●
The control unit is for indoor use only. Observe the
following conditions:
- Install it with vertical orientation having enough space
from other devices.
- 0 to 40
°
C, 95%RH or less (No condensation)
- No vibration, no shock
- No water or oil drips
- No corrosive gas, no explosive gas, no dust, or no
powder.
Make sufficient noise suppression and grounding.
●
Electric noise on a signal wire may cause result in unit
malfunction or unexpected occurrence of troubles.
Keep the following conditions:
- Separate signal wires from power lines.
- Make electric wires short as much as possible.
- Actuators and control units should be grounded at one
single point having grounding resistance class 3 or more.
- Do not use a power line filter into motor circuit.
Notices for operation: Always read the relating technical documents for the purpose.
Do not change wiring whenever power supply is
active.
●
Turn power OFF at first, then disconnect or connect
connectors or wires. Getting an electric shock or
abnormal damage may occur by changing wire
during power active.
Do not touch a terminal after at least five minutes
from power-OFF.
●
Even after power-OFF, electric charge remains in the
control unit. To avoid an electric-shock-accident,
inspection must start after five minutes from
power-OFF.
●
The control unit should be housed in a cabinet box
designed not to touch electric parts easily/
Do not make a withstanding voltage test.
●
Do not make a withstand test or a voltage resistance
test. The test causes damage to the control unit.
●
For this type of use, consult with us.
Do not operate a control unit by means of power
ON/OFF operation.
●
The frequent power ON/OFF operation may cause
deterioration of the electric elements.
●
Start/stop operation should be performed by means of
input signals.
In case of power failure, turn off the power of the
control unit and driver.
●
Failure to do so may cause injury or damage to the
device due to sudden restart.
Do not touch the actuator with wet hands.
●
It may cause an electric shock.
Do not repair, disassemble, or modify it.
●
It may cause an electric shock, injury, or fire. Also,
the initial performance may not be reproduced.
Abandonment of an actuator and servo driver:
Abandon an actuator and motor as industrial waste.
●
Upon disposal, disassemble it as much as possible, separate parts with indicated materials according to the markings, and
dispose of them as industrial waste.
CAUTION
CAUTION
WARNING
WARNING
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION