Chapter 7
Parameter details
-
-
44
Chapter 7 Parameter details
7-1
Default setup parameters
The following table summarizes the default parameters:
Display
Parameter name
Unit
Actuator model
RSF-8
RSF-11
RSF-14
1/50
1/100
1/50
1/100
1/50
1/100
00
Position error allowance
Pulse
30,000
30,000
30,000
30,000
30,000
30,000
01
In-position range
Pulse
10
10
10
10
10
10
02
Position loop gain Note
s
-1
40
40
50
50
40
40
03
Speed loop proportional gain
Note 1
-
60
60
70
70
60
60
04
Speed loop integral gain Note 1
-
5
5
5
5
5
5
05
Speed loop action gain
-
0
0
0
0
0
0
06
Speed feed forward factor
-
0
0
0
0
0
0
07
Acceleration feed forward factor
-
0
0
0
0
0
0
08
Torque command filter
-
0
0
0
0
0
0
09
Rotational direction command
-
1
1
1
1
1
1
10
Electronic gear - numerator
-
1
1
1
1
1
1
11
Electronic gear -
denominator
-
1
1
1
1
1
1
12
Speed step correction
-
0
0
0
0
0
0
13
Torque step correction
-
0
0
0
0
0
0
14
-
Note 3
-
0
0
0
0
0
0
15
Forward torque limit
Note 2
%
158
147
140
150
240
220
16
Reverse torque limit Note 2
%
158
147
140
150
240
220
19
JOG speed
r
/min
500
500
500
500
500
500
20
JOG feed pulse count
Pulse
100
100
100
100
100
100
24
Step correction switching range
Pulse
4000
4000
4000
4000
4000
4000
28
Control input filter time constant
ms
0
0
0
0
0
0
29
-
Note 3
-
0
0
0
0
0
0
31
Command pulse input configuration
-
2
2
2
2
2
2
33
-
Note 3
-
0
0
0
0
0
0
38
Input pin logic setting
-
0
0
0
0
0
0
39
Output pin logic setting
-
4
4
4
4
4
4
40
JOG acceleration/deceleration
ms
500
500
500
500
500
500
41
CLEAR signal function selection
―
1
1
1
1
1
1
42
Multiplication of 2-phase pulse
―
4
4
4
4
4
4
43
JOG character-S selection
―
0
0
0
0
0
0
44
Communication condition
―
12
12
12
12
12
12
45
Speed limit Note 2
r
/min
5100
5100
5100
5100
5100
5100
46
Dynamic break on/off
―
1
1
1
1
1
1
47
Regeneration brake on/off
―
0
0
0
0
0
0
Note: For the procedure for changing a parameter setting, refer to
“
Chapter 6, Operating the display panel".
Note 1: The actual setting varies with the AC servo actuator model. When changing the setting, consider this default
as the standard (guide setting).
Note 2: The maximum value that is determined, depending on the AC servo actuator model. No value above this can
beset.
Note 3: Do not change the setting. If it is changed, the alarm will be unable to operate normally.